Itf Minimum Symbol Length Test; Msi Plessey Check Digit - Metrologic MS951 Programming Manual

Hand-held laser scanner
Hide thumbs Also See for MS951:
Table of Contents

Advertisement

Enter/Exit Program Mode

ITF Minimum Symbol Length Test

A custom minimum character length can be configured for only ITF bar
codes. This leaves shorter minimum lengths for other code types possible. The
scanner will not scan codes with fewer than the configured minimum of
characters. To activate, first scan an ITF character lock length. Then scan
RBC-enable minimum test. This feature overrides ITF character locking.
Enable ITF Minimum
Symbol Length Test
R
B
C
Disable ITF Minimum
Symbol Length Test
R
B
D

MSI Plessey Check Digit

Enable MSI Plessey
When this option is enabled, the scanner will
scan MSI Plessey bar codes.
R
0
2
** Disable MSI Plessey
R
**Enable MSI Plessey Test of Check Digit
When this option is enabled, the scanner will
R
0
4
check the MSI Plessey bar code for a proper
check digit.
Disable MSI Plessey Test of Check Digit
R
**Enable MSI Plessey
When this option is enabled, the scanner will
Mod 10 Check Digit
scan MSI Plessey bar codes that have a single
Modulo 10 check digit.
R
0
6
42
*
*
0
3
0
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents