ITF Minimum Symbol Length Test

A custom minimum character length can be configured for only ITF bar
codes. This leaves shorter minimum lengths for other code types possible.
The scanner will not scan codes with less than the configured minimum of
characters. To activate, first scan an ITF character lock length. Then scan
RBC-enable minimum test. This feature overrides ITF character locking.
Enable ITF Minimum
Symbol Length Test
R
B
C
Disable ITF Minimum
Symbol Length Test
R
B
D

MSI Plessey Check Digit

Enable MSI Plessey
R
0
2
**Enable MSI Plessey Test of Check Digit
R
0
4
**Enable MSI Plessey
Mod 10 Check Digit
R
0
6
42
Enter/Exit Program Mode
*
*
When this option is enabled, the scanner will
scan MSI Plessey bar codes.
** Disable MSI Plessey
R
0
3
When this option is enabled, the scanner will
check the MSI Plessey bar code for a proper
check digit.
**Disable MSI Plessey Test of Check Digit
R
0
5
When this option is enabled, the scanner will
scan MSI Plessey bar codes that have a single
Module 10 check digit.