PROCEDURE TO WRITE DATA INTO EE-PROM (IC1402)
1. Procedure to change the EE-PROM and write the
initial value of the microprocessor into EE-PROM
(1) Replace the EE-PROM.
(2) Refer to the latest "List of EE-PROM contents".
(3) Press the POWER button while pressing the INPUT
button and the STOP button to start the test mode.
(4) Version on display
Version of EEPROM protect data (from 01)
t s m 1 3 * * e * *
Version of microprocessor ROM (from 01)
(5) Load a disc.
[ AUT YOBI ]
(6) Press the DISPLAY button (REMOCON) 6 times.
[ EEPROM SET ]
(7) Perform the procedure to have "EE-PROM setting
mode transition diagram" displayed, compare it with
"List of EE-PROM contents" and set to "List of EE-
PROM contents" by using the jog dial.
(8) Set the temperature standard value.
(Refer to "Procedure to set the temperature standard
value".)
(9) Use the same settings as "List of EE-PROM con-
tents" for all.
10) Set to the TEST mode and perform AUTO pre-
adjustment and AUTO adjustment.
11) Cancel the TEST mode by pressing the REC/PAUSE
button (REMOCON).
(Writing into EEPROM starts from here.)
2. Procedure to set the temperature standard value
(This setting should be performed within the room
temperature range of 21 ˚C - 29 ˚C.)
(1) Have the AUTO pre-adjustment mode menu dis-
played.
[ AUT YOBI ]
(2) Compensate the temperature to be suitable for the
ambient temperature, referring to the table below.
Ambient temperature
+ 21.0 ˚C - + 23.2 ˚C
+ 23.3 ˚C - + 26.8 ˚C
+ 26.9 ˚C - + 23.7 ˚C
Example : When the ambient temperature is 22 ˚C
and the temperature measured value is 7A
Temperature set value = 7A
* When the measured temperature deflects between 2
values, use the smaller one as the measured value
(79
if measured values are 7A
H
(3) Press the DISPLAY button (REMOCON) 6 times.
[ EEPROM SET ]
(4) Press the SET/ENTER button (REMOCON) 7 times.
Focus
[
15
Compensation value
– 01
H
± 0
H
+ 01
H
H
– 01
H
H
= 79
H
and 79
).
H
H
]
(5) Press the DISPLAY button (REMOCON) 4 times.
Temp
[
]
(6) Press the SET/ENTER button (REMOCON).
[ TEMP
]
: Temperature measured value
: Temperature set value
(7) Adjust the temperature set value to the value ob-
tained as described above by using the jog dial.
(8) Press the DELETE/CANCEL button (REMOCON).
Temp
[
]
LIST OF EE-PROM CONTENTS
Focus setting
Item on display
FG
FF1
FF2
FZHLEV
FOKLEVn
FOKLEVf
FOKLPFn
FOKPFVf
WAITf
Spin setting
Item on display
SPG
SPG-in
SPG-mid
SPG-out
SP1
SP2
SP3
SP4
SP5
SPDLIM
Tracking setting
Item on display
TG
TF1
TF2
SVCNT4
TRBLVo
TRBLVt
TRkLVo
TRkLVt
TDPWo
TDPWt
SLCTo
SLCTt
SLCTm
TCRSCIP
COTLVP
COTLVr
WAITm
Set value
DA
H
70
H
E0
H
ED
H
08
H
08
H
00
H
88
H
90
H
Set value
20
H
B8
H
95
H
79
H
10
H
87
H
E3
H
E3
H
10
H
7F
H
Set value
6B
H
6B
H
E0
H
00
H
50
H
54
H
50
H
2E
H
89
H
1A
H
00
H
40
H
53
H
16
H
0A
H
1C
H
FF
H