Fault Display Code - Hisense RD-44WC series Service Manual

No frost
Table of Contents

Advertisement

Fault display code

1.If there is a temperature sensor fault, fan fault or defrosting timeout fault, each time you open the refrigerator
door, the corresponding LED light flashing 30 seconds on the display board.
2.When freezer temperature sensor occur failure: refrigeration temperature display area D1 Light flash 30
seconds.
3. When the freezer temperature sensor occur failure: frozen temperature display area F1 lights flash 30 seconds.
4. When the defrosting sensor occur failure: frozen temperature display area F2 indicator light flash 30 seconds.
5. When the refrigerant evaporating fan occur failure: frozen temperature display area F3 indicator light flash 30
seconds.
6. When the defrosting heater heating time arrive to the limit time, frozen temperature display area F4 indicator
light flash 30 seconds.
7. when the refrigerator door open time more than 2 minutes and less than 12 minutes, refrigerator door
temperature display area D5 indicator lights indicating until the refrigerator door closed.
8. when frozen door open time more than 2 minutes and less than 12 minutes, the freezing temperature display
area F5 indicator lights indicating until frozen door closed.
9. When communication occur failure refrigeration temperature display area D2 indicator lights indicating until the
communications back to normal.
When the fault is eliminated, it turns to normal display.
Using a multimeter with the ohm switch to measure the resistor of sensor, normally at surrounding 25℃ the
resistor should be about 2kohm and every with the temperature decreases 1℃ the corresponding resistor value
would increase about 45ohm. If the measured value is not within the normal scope, the sensor is bad and needs
to repair or change.