Download Print this page
Master MH-375T-GFA-A User's Manual & Operating Instructions

Master MH-375T-GFA-A User's Manual & Operating Instructions

Hide thumbs Also See for MH-375T-GFA-A:

Advertisement

User's Manual & Operating Instructions
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
DANGER
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS
OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON
MONOXIDE POISONING AND / OR ELECTRIC SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE
OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS
MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID
WARNING
COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR
CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY
THESE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY
CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS.
668 Stony Hill Road #302 Yardley, PA 19067 USA
Fax: (215)-891-8461
Model Number
MH-375T-GFA-A
© 2014 Pinnacle Products International, Inc.
• Web: www.masterindustrialproducts.com • Email: info@pinnacleint.com
Toll Free (800)-641-6996
221000133-14

Advertisement

loading

Summary of Contents for Master MH-375T-GFA-A

  • Page 1 User’s Manual & Operating Instructions Model Number MH-375T-GFA-A CONSUMER: READ AND SAVE THESE INSTRUCTIONS GENERAL HAZARD WARNING: DANGER FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN.
  • Page 2: Table Of Contents

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Table Of Contents Safety Information..........1-3 Wiring Diagrams...........9 Specifications and Features........4 Troubleshooting Guide........10 Operation............5-7 Exploded View...........11 Ventilation............8 Parts List............12 Maintenance............8 Warranty.............13 Safety Information NOT FOR HOME OR RECREATIONAL VEHICLE USE.
  • Page 3: Safety Information

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Safety Information RISK OF INDOOR AIR PROPANE IS AN WARNING DANGER POLLUTION! EXPLOSIVE GAS. The products described in this manual are WHAT TO DO IF THE SMELL OF GAS IS PRESENT: propane direct-fired, forced air heaters.
  • Page 4 – This heater is shipped from the factory for use with propane (LP) gas only. Do not Minimum and Maximum Supply Pressure convert to any other gas. Installation must MH-375T-GFA-A conform to local codes, or in their absence, Min. 23 PSI with the standard for the Storage and Max.
  • Page 5 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Specifications Model # MH-375T-GFA-A 225-375,000 Fuel Consumption (Lbs./hr) 10.4 / 17.4 Maximum Operating Hours 11.5 Required Cylinder Lbs. Fuel Type Propane Heating Area (Ft.
  • Page 6: Operation

    – The temperature of the LP tank and its This heater is not supplied with a propane cylinder. surroundings. Use only an approved propane cylinder. Average Temp MH-375T-GFA-A LP Characteristics (ºF) 100 lb. Cylinder – Flammable, explosive under pressure, heavier 40º...
  • Page 7 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Operation Pre-Lighting Instructions: – With heater gas valve knob still in OFF Connecting the LP Cylinder position turn ON the LP cylinder valve and check for leaks with soap solution.
  • Page 8 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Operation Lighting Instructions: NOTE: If the heater still does not start, turn Starting the Heater (Ignition) power switch to OFF position and wait 10 1.
  • Page 9: Ventilation

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Ventilation CARBON MONOXIDE POISONING MAY LEAD TO DEATH! DANGER – Risk of indoor air pollution and Carbon Monoxide Poisoning. Use heater only in Minimum Ventilation Opening Needed well ventilated areas.
  • Page 10: Wiring Diagrams

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Wiring Diagram MH-375T-GFA-A SENSOR white Blue SPARK IGNITOR Blue MODULE MOTOR SOLENOID VALVE GREEN GREEN Blue white Blue SPARK MODULE Black Blue...
  • Page 11: Troubleshooting Guide

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Troubleshooting Guide Locating Your Serial Number: Your serial number can be found on a white label on the right side cover of your heater. It will begin with the letters “HGF”...
  • Page 12: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Exploded View 6, 8 27, 33 Figure 7 © 2014, Pinnacle Products International, Inc. Propane Forced Air Heater User’s Manual...
  • Page 13: Parts List

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE Parts List Item # Description MH-375T-GFA-A Inner Shell 22-524-0012 Outer Shell 22-524-0078 Handle 22-511-0004 Thermal Switch 22-603-0003 Thermal Switch Cable 22-601-0006 Spark Plug...
  • Page 14 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE LIMITED WARRANTY Pinnacle Products International, Inc. warrants this heater If Pinnacle Products International, Inc. finds the item to to the original retail purchaser only, to be free from defects be in normal operating condition, or not defective the item in material and workmanship for a period of one (1) year will be returned freight collect.
  • Page 15 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________...
  • Page 16 © 2014 Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19067 USA • Toll Free (800)-641-6996 Fax: (215)-891-8461 • Web: www.pinnacleint.com • Email: info@pinnacleint.com...