TB7200 SERIES COMMUNICATING ZONE THERMOSTATS

TB7200 Series Model Selection

Product Number
BACnet Models
TB7200C5014B
Modulating with Reheat
TB7200C5514B
Modulating with Reheat
TB7200F5014B
Modulating with Reheat
TB7200F5514B
Modulating with Reheat
Wireless Models
TB7200C5014W
Modulating with Reheat
TB7200C5514W
Modulating with Reheat
TB7200F5014W
Modulating with Reheat
TB7200F5514W
Modulating with Reheat
Accessories
TB-PIR-ZN
Zone Occupancy Sensor Cover
TB-RA-1014
Wireless Remote Antenna Base
TB-RP5000W
Wireless Repeater for TB7XXX Series Wireless
Thermostats
TBST-5014W
ZigBee Wireless Survey Toolkit
TB-VWG-APP-1014 TB7XXX Series Wireless Communication Card
TB-WALL-1014
Room Sensor 10K NTC Type 2
TB-WALLOVR-1014 Room Sensor with Override 10K NTC Type 2
1 Thermostats ordered without an occupancy sensor cover can be retrofitted with the cover at a later time if required

More Information

We recommend downloading the appropriate integration reference document (wireless or BACnet) and if installing
thermostats with occupancy sensor covers, then also downloading the PIR Application Guide before you begin
installation. All documentation is available on http://customer.honeywell.com.
— BACnet Integration Manual for TB7200 and TB7300 Series Thermostats (Form No. 63-4524)
— Wireless Installation & Integration Reference Guide for TB7200, TB7300, and TB7600 Thermostats
(Form No. 63-4522)
— PIR Application Guide for TB7200 and TB7300 Thermostats (Form number 63-4526)
— Sensors Product Overview Brochure (Form No. 63-9285) provides a complete listing of compatible sensors.

INSTALLATION AND WIRING

Mounting Location

• Do not install on an outside wall
• Must be installed away from any heat source
• Should not be installed near an air discharge grill
• Should not be mounted in direct sun light
• Nothing must restrain vertical air circulation to the thermostat
• Wall surface must be flat and clean
IMPORTANT
If replacing an old thermostat, label the wires before removal of the old thermostat.
CAUTION
• Electronic controls are static sensitive devices. Discharge yourself properly before manipulation and
installing the thermostat.
• Short circuit or wrong wiring may permanently damage the thermostat or the equipment.
• Anti-short cycling can be set to 0 minutes for equipment that has an anti cycling timer. Do not set to 0 unless
the equipment has internal anti-cycling timer or damage to equipment can occur.
• All TB7200 series thermostats are to be used only as operating controls. Whenever a control failure could
lead to personal injury and/or loss of property, it becomes the responsibility of the user to add safety devices
and/or alarm system to protect against such catastrophic failures.
62-2019—05
Description
2
Outputs
2 floating or on/off + 1 Aux
2 floating or on/off + 1 Aux
2 0-10Vdc + 1 Aux
2 0-10Vdc + 1 Aux
2 floating or on/off + 1 Aux
2 floating or on/off + 1 Aux
2 0-10Vdc + 1 Aux
2 0-10Vdc + 1 Aux
Occupancy
1
Sensor
Ready
Yes
Ready
Yes
Ready
Yes
Ready
Yes

Advertisement