Meridian Cd Does Not Respond; Or 604 Does Not Respond; Or 601 Does Not Respond - Meridian DSP5000 User Manual

Meridian user manual loudspeaker dsp5000
Hide thumbs Also See for DSP5000:
Table of Contents

Advertisement

2. If clicks occur randomly with the source selected but stopped, the
problem may be the result of loss of lock due to gross electrical
interference. Find out whether there is an appliance elsewhere in the
house causing the disturbance (e.g. central heating, a pump or a fan). If
there is, suppress it.

Meridian CD does not respond

1. Check that all connections between the master speaker and the
Meridian CD player have been made correctly
2. Make sure that the whole system is set up in either 200 mode or in 500
mode.
Note All Meridian products must be in the same mode. 200 or 600-Series
products can only work in 200 mode and if you intend to incorporate these
in a DSP5000 system, the speakers and any 500-Series components
must be put into 200-mode (normally Type 2).
3. Make sure that the DSP5000 has been set up so that this source is
Comms type '1C' – see page 38.
4. Make sure that the Comms address corresponds in DSP5000 and in
the CD player (normally '1A') – see page 38.

504, 204 or 604 does not respond

1. Check that all connections between the master and the 504/204/604
have been made correctly. If a 204/604 is the only other Meridian
equipment in the system you will need an SP5 adapter to allow the
M5-lead to connect to the socket marked CD on the 204/604.
2. Check that a 204 is fitted with software of an adequate level. DSP5000
requires version 204.A or later. To see the version, press Mode * Set
on the front panel of the 204 when the unit is not in Standby. Version
numbers count 1–9, then A–Y. If the software in your 204 is earlier
than 204.A, your dealer will be able to obtain an up-to-date EPROM
and fit it. Operating code can always be updated.
2. Make sure that the whole system is set up in either 200 mode or in 500
mode.
Note All Meridian products must be in the same mode. 200 or 600-Series
products can only work in 200 mode and if you intend to incorporate these
in a DSP5000 system, the speakers and any 500-Series components
must be put into 200-mode (normally Type 2).
3. Make sure that the DSP5000 has been set up so that this source is
Comms type '2C' – see page 38.
4. Make sure that the Comms address corresponds in DSP5000 and in
the CD player (normally '1A') – see page 38.

562, 201, 603 or 601 does not respond

1. Check that all connections have been made between the master and
the preamplifier. If the preamp is the only other Meridian equipment in
the system you will need an SP5 adapter to allow the M5-lead to
connect to the 200/600 Comms socket on the preamp.
2. Check that a 201 is fitted with software of an adequate level. DSP5000
requires 201.7 or later for 201MkII, or 0.4 or later for 201MkIII. To find
out which version you have, follow the instructions in the manual
supplied with the 201. Version numbers count 1–9, then A–Y. If the
software in your 201 is earlier than 201.7, your dealer will be able to
Help
51
DSP5000 User Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents