Schematic, Electrical Up6 5–15Hp Sd 3Ph 60Hz - Ingersoll-Rand SSR UP5-4 Operation And Maintenance Manual

50 & 60 hz
Table of Contents

Advertisement

Available languages

Available languages

GeneRAL InFORMATIOn
SCHeMATIC, eLeCTRICAL UP6 5–15HP SD 3PH 60Hz
KeY
1FU, 2FU
Fuse, primary
FU
Fuse, secondary
FU, 5FU
Fuse, dryer
1LT
Light, power on indicator (green)
2LT
Light, auto restart indicator (white)
1M
Contactor, main
1Ma, b, c
Contacts, auxiliary. Main contactor
2M
Contactor, delta
2Ma, b
Contacts, auxiliary. Delta contactor
1S
Contactor, star
1Sa, b
Contacts, auxiliary. Star contactor
1SV
Valve, solenoid (nc)
CPT
Transformer, control
CR
Relay, control
CRa
Contact, control relay
CS
Customer supplied 115v / 1 / 0hz
DM
Motor, dryer
DO
Dryer option
EDV
Valve, electric drain (optional)
E–STOP
Switch, emergency stop
1
OPeRATIOn AnD MAInTenAnCe MAnUAL
HATS Switch, high air temperature
HM
Hourmeter
HM1
Indicator, maintenance
MIO
Indicator, maintenance option
(Instead of standard hourmeter)
MTR
Motor, compressor
OL
Overload, main motor
OLa
Contact, main motor overload
PS
Switch, pressure
ST
Push button, start
T D
Relay, delta starting (10sec)
TDc
Relay, delay off, contact
nOTeS
1.
(*) Furnished, mounted and wired outside of control
panel, if required by order.
2.
Circuit shown in normal position de–energized.
.
All wiring to be marked in accordance with this
schematic.
.
All wiring to be in accordance with NEC.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents