Technical Details Intermittent Operation
Intermittent operation is when the appliance is used for short firing periods for example 45 minutes to 2 hours.
This is a common operation in warmer weather such as cold spring evenings. The information provided below
where indicated as HETAS approved is from the current CE standards EN 13240:2001 and EN 13240 A2:2004. The
test fuel for wood burning, beech.
Model
Model
Name
Number
Cult
RKC1
Cult Plus
RKC2
Eco
RKE1
Eco Plus
RKE2
Fox
RKF1
Jazz
RKJ1
Scena
RKS1
Tara
RKT1
Tema
RKT5
Twist
RKT2
Vitra
RKV1
* With soapstone cladding
Free Air Requirement
Air requirement equivalent area. Building regulations Document J, advises that an air supply,permanently open
vents, should be installed for appliances:
If design air permeability >5.0m³/(h.m²) then 550mm²/kW of appliance rated output above 5kW
or
If design air permeability <5.0m³/(h.m²) then 550mm²/kW of appliance rated output
Equivalent air is as measured according to the method in BS EN13141-1:2004
It is unlikely that a dwelling constructed prior to 2008 will have an air permeability of <5.0m³/(h.m²) at 50pa
unless extensive measures have been taken to improve air-tightness.
Useful Organizations UK
Solid Fuel Association
The National Association of Chimney Sweeps
HETAS Ltd.
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. July 2011
Heat
Output
Loading
Weight
Nominal
Rate
Wood
6kW
1.6 kg/h
6kW
1.6 kg/h
8kW
2.0 kg/h
8kW
2.0 kg/h
8kW
2.0 kg/h
8kW
1.7 kg/h
10kW
2.5 kg/h
8kW
2.0 kg/h
6kW
1.6 kg/h
8kW
2.0 kg/h
4kW
1.2 kg/h
_
Flue
Flue Gas
Draught
Mass
KG
Nominal
Flow g/s
182
12pa
5.2
222*
158
12pa
5.2
238*
298
10pa
6.4
298
10pa
6.4
120
10pa
9.5
240*
214
12pa
6.4
240
12pa
8.2
130
10pa
9.5
390*
125
12pa
5.2
180*
240
12pa
6.9
158
11pa
5.1
238*
0845 601 4406
01785 811732
0845 634 5626
4
Flue Gas
Efficiency
Temperature
with
Down Stream
Top Flue
of Flue Spigot
Connection
deg C
83.2% Net
221
75.7% Gross
83.2% Net
221
75.7% Gross
79.1% Net
223
72.0% Gross
79.1% Net
223
72.0% Gross
80.1% Net
187
73.8% Gross
77.2% Net
240
70.0% Gross
80.1% Net
280
72.8% Gross
80.1% Net
187
73.8% Gross
83.2% Net
226
75.7% Gross
79.3% Net
260
72.2% Gross
80.9% Net
206
73.6% Gross
www.solidfuel.co.uk
www.chimneyworks.co.uk
www.hetas.co.uk
E & OE
Instructions Part number IN1210 Ed.2
Flue outlet
size
153mm/6"
153mm/6"
153mm/6"
153mm/6"
153mm/6"
153mm/6"
153mm/6"
153mm/6"
125mm/5"
153mm/6"
153mm/6"