INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your
primary heating system. Do not install this heater as your primary heat source.
WARNING: A qualified technician must install heater. Follow all local codes.
WARNING: Maintain the minimum clearances. If possible, provide greater clearances from the
floor, ceiling, and adjoining wall than required.
CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces
next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where
impurities (such as tobacco smoke, candles, cleaning fluids, oil or kerosene lamps, etc.)
in the air exist, may cause walls to discolor.

CLEARANCES TO COMBUSTIBLES

Carefully follow the instructions below. This heater can be mounted on the wall or on the floor using
the support legs (Select models).
WARNING: Maintain the minimum clearances shown in (See Fig. 3). If you can, provide greater
clearances from floor, ceiling, and joining wall.
*LEFT   /   R IGHT  
8   i n.
Top   c learance   i s   f rom   t op   o f   h eater   t o   c eiling,   w ood   s helf   o r   o ther   c ombustible   m aterial
Bottom   c learance   i s   f rom   b ottom   o f   h eater   t o   s urface   o f   c arpet,   t ile   o r   o ther   c ombustible   m aterial.
*A second side wall must be at least 18 in. away from the other side of the heater.
Always maintain a minimum of 36 in. clearance from furniture and draperies.
*For the installation in residential garages please refer to the bottom of page 4.
Fig. 3 - Mounting clearances as viewed from
front of heater (inches)
CEILING
8 in.
Minimum
From
Side of
Heater
LEFT SIDE
36 in. Minimum from
Furniture and Draperies
FRONT
FLOOR
*A Second Side Wall Must be at Least 18in.
Away from the Other Side of the Heater.
MINIMUM   C LEARANCE   T O   C OMBUSTIBLES
TOP  
36   i n.
36 in.
Minimum
RIGHT SIDE
3 in. Minimum to Top Surface of Carpeting,
Tile or Other Combustible Material
BOTTOM
FRONT
3   i n.
36   i n.
11
Rear
0   i n.   t o   S pacer