Drive Manual Operation - Sony DVP-S335 Service Manual

Cd/dvd player
Hide thumbs Also See for DVP-S335:
Table of Contents

Advertisement

4. SACD
[4]
Select
, insert SACD disc, and press
adjustment will be made through the following steps, then adjusted
values will be written to the EEPROM. However, if SACD disc is
not available, use the player with initial data, skipping the SACD
adjustment. In this case, you can finish the adjustment if pressing
[STOP]
the
button.
SACD Adjustment Steps
1. Sled Tilt Reset
2. Set Disc Type CD
3. LD ON
4. Spdl Start
5. Wait 1 sec
6. Focus Servo ON 0
7. Auto track Offset Adjust
8. Tracking ON
9. CLVA ON
10. Wait 1 sec
11. Sled ON
12. Check CLV ON
13. Auto LFO Adjust
14. Auto Focus Offset Adjust
15. Auto Focus Gain Adjust
16. Auto Focus Offset Adjust
17. Eq Boost Adjust
18. Auto LFO Adjust
19. Auto Track Gain Adjust
20. All Servo Stop

6-5. DRIVE MANUAL OPERATION

[ENTER]
key, and the
On the Test Mode Menu screen, select
tion menu will be displayed. For the manual operation, each servo
on/off control and adjustment can be executed manually.
In using the manual operation menu, take care of the following
points. These commands do not provide protection, thus requiring
correct operation. The sector address or time code field is dis-
played when a disc is loaded.
Basic operation (controllable from front panel or remote com-
mander)
[POWER]
[STOP]
[OPEN/CLOSE]
[RETURN]
[NEXT]
[1]
Cursor UP/DOWN
6-7
## Drive Manual Operation ##
Operation Menu
1. Disc type
2. Servo Control
3. Track/Layer Jump
4. Manual Adjustment
5. Auto Adjustment
6. Memory Check
0. Disc Check Memory
Exit: Return
1. Set correctly the disc type to be used on the Disc Type
screen.
The disc type must be set after a disc was loaded.
The set disc type is cleared when the tray is opened.
2. After power ON, if the Drive Manual Operation was se-
lected, first perform "Reset SLED TILT" by opening 1.
Disc Type screen.
3. In case of an alarm, immediately press the
ton to stop the servo operation, and turn the power OFF.
Power OFF
Servo stop
Stop+Eject/Loading
Return to Operation Menu or Test Mode
Menu
[PREV]
,
Transition between sub modes of menu
[9]
[0]
to
,
Selection of menu items
Increase/Decrease in manually adjusted
value
[2]
, and the manual opera-
[STOP]
but-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvp-s345Dvp-s535dDvp-s735dDvp-s336

Table of Contents