6-6-3. Manual Control 1
Manual Control 1
SA.000000
SI.00
EMG.00
0. LD
off
7. CLVA
1. SP
off
8. CAV
2. Tilt
off
9. Home
→. Sled FWD
3. Focus
off
←. Sled RVS
4. Track
off
↑ . Tilt Up
5. Sled
off
↓ . Tilt Down
6. AGC
off
DVD SL
12cm
Figure 13
On this screen, turn on/off servo operation items necessary for
playing.
Normally, turn on the items from 0 sequentially, and normal trace
is executed at CLVA. In the tracking status, the sector address (or
time code (at CD)) is displayed.
If not displayed, the spindle is not locked, which means a failure.
In case of spindle system failure or no RF, the spindle system may
run, overriding the control.
In this case, do not press the CLVA.
0. LD
: Turn on/off the laser diode.
1. SP
: Turn on/off the spindle.
At SP ON, the spindle runs in constant velocity mode.
2. TILT : Turn on/off the tilt servo.
3. Focus : Focus searching is executed and focus is turned on.
Operation is terminated if focus is not turned on after
focus search is retried about 3 times.
4. Track : Turn on/off the tracking servo.
5. Sled : Turn on/off the sled servo.
6. AGC : Turns on/off the focus error auto gain control by PULL
IN level.
7. CLVA : Spindle normal servo.
8. CAV : Spindle in constant velocity mode
9. Home : Return to home position.
→.
: Move the sled system outside.
Perform this with the tracking turned off.
←.
: Move the sled system inside.
Perform this with the tracking turned off.
↑ .
: Move the tilt system up.
↓ .
: Move the tilt system down.
6-14