Panasonic CS-A9CKPG Service Manual page 36

Table of Contents

Advertisement

CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
NAME OF EACH PART
I Remote Control
1
2
3
4
5
6
7
8
9
0
G Remote Control Signal
• Make sure it is not obstructed.
• Maximum distance : 10 m (32.8 ft.).
• Signal received sound :
One short beep or one long beep.
G Notes for Remote Control
• Do not throw or drop.
• Do not get it wet.
• Certain types of fluorescent lamps may affect
signal reception. Consult your dealer.
PREPARATION BEFORE OPERATION
I Indoor Unit
5
2
4
3
1
Open the front panel
AUTO HEAT
2
Remove the air filters
3
Fit the air purifying filters in place
4
Insert the air filters
5
Close the front panel
I Remote Control – To set the current time
AIR SWING
AUTO
1
ON
OFF
CHECK
RESET CLOCK
1
Press 1.
2
Then press 2 to increase or decrease the time.
3
Press 1 again.
Set time on display will light up.
1 Signal Transmitter
2 Operation Display
3 Quiet Mode Operation Button
4 Room Temperature Setting Button
AUTO HEA
AUT
HEAT
COOL
COOL
DR
DRY FAN
AN
AUTO
5 Operation Mode Selection Button
ON
6 Economy Mode Operation Button
AUTO
OFF
FAN
TEMP
7 Auto Airflow Direction Button
OFF/ON
QUIET
!
8 ON-Timer Button
#
9 OFF-Timer Button
MODE
ECONOMY
POWERFUL
AIR SWING
$
0 Reset Point
AUTO
MANUAL
FAN SPEED
$
1
2
3
%
ON
SET
! OFF/ON Button
^
OFF
CANCEL
&
TIMER
*
@ Powerful Mode Operation Button
CHECK
RESET CLOCK
(
# Fan Speed Selection Button
$ Manual Airflow Direction Selection Button
% Timer Set Button
^ Timer Cancellation Button
& Time-Setting Button
* Clock Button
( Remote Control Cover
HOW TO OPERATE
1
COOL
DRY FAN
AUTO
I To start the operation
• Press 1.
AUTO
• POWER indicator (green) on the indoor unit will light
FAN
up.
• To stop, press once more.
I Setting Mode
• Press 2 to select:-
MANUAL
FAN SPEED
2
3
SET
CANCEL
2
TIMER
1
(Illuminating button)
(Press with fine-tipped object to clear the memory)
(Illuminating button)
2
3
5
1
6
4
Cooling Model
AUTO
– Automatic Operation
COOL
– Cooling Operation
DRY
– Soft Dry Operation
FAN
– Air Circulation Operation
Heat Pump Model
AUTO
– Automatic Operation
HEAT
– Heating Operation
COOL
– Cooling Operation
DRY
– Soft Dry Operation
36
G How to Insert the Batteries
2
1
Slide down the remote control cover completely
to remove it.
2
Insert the batteries
– Be sure the direction is correct
– 12:00 on display - flashing
• Set the current time (CLOCK) immediately to
prevent battery exhaustion.
3
Re-install the remote control cover by inserting it
in the side groves and pushing inward.
G About the batteries
• Can be used for approximately one year.
G Observe the following when replacing the
batteries
• Replace with new batteries of the same type.
• Do not use rechargeable batteries (Ni-Cd).
• Remove the batteries if the unit is not going to be
used for a long period.
I Setting Temperature
• Press 3 to increase or decrease the temperature.
• The temperature can be set between 60°F ~ 86°F.
• Recommended temperature:
Cooling Model
Heat Pump Model
COOL –> 75°F ~ 78°F
COOL –> 75°F ~ 78°F
DRY
–> 2°F ~ 4°F
DRY
–> 2°F ~ 4°F
lower than the
lower than the
room temperature
room temperature
HEAT –> 68°F ~ 75°F
• During AUTO Operation, press 3 to select:-
• Operation with 4°F higher than the standard
temperature.
• Operation with the standard temperature.
• Operation with 4°F lower than the standard
temperature.
G Standard Temperature
Cooling Model
Standard
Indoor
Operation
temperature
temperature
Cooling
77°F
73°F
Soft Dry
72°F
• Once the Automatic Operation is selected, the indoor
temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.
• After the operation mode has been selected, the
mode does not change.
Heat Pump Model
Standard
Indoor
temperature
Operation
temperature
Cooling
77°F
Soft Dry
72°F
73°F
68°F
Heating
70°F
• At the beginning of the automatic operation, Heating,
Cooling or Soft Dry is automatically selected according
to the indoor temperature.
• The operation mode changes every hour, when
necessary.
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-a12ckp6gCs-a12ckpgCu-a9ckp6g

Table of Contents