Panasonic CS-A9CKPG Service Manual page 16

Table of Contents

Advertisement

CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Compressor Protection Control
• After the compressor starts for 50 seconds but the outdoor fan motor is still OFF, the compressor will stop and restart
automatically. (Time Delay Safety Control is valid).
• If the above phenomenon is repeated for 3 times, the compressor will stop totally.
• The above phenomenon is reset when there is a change to heating mode or stopped by Remote Control Switch.
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during cooling operation.
• Fan speed rotates in the range of Hi to Me.
• Deodorizing Control.