Broan B5936SS Instructions Manual
Hide thumbs Also See for B5936SS:
Table of Contents

Advertisement

Available languages

Available languages

CHIMNEY

RANGE HOOD

READ AND SAVE THESE INSTRUCTIONS
VQ0009
WARNING
!
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSON(S) OBSERVE THE
FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switch on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA), the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any other solid-state speed control
device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods (i.e. Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filters.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
INSTALLER: LEAVE THIS GUIDE TO THE HOMEOWNER.
HOMEOWNER: OPERATION AND MAINTENANCE INFORMATION ON PAGE 8.
To register this product visit:
I
!
ntended for domestIc cookIng only
www.broan.com
WARNING
!
VQ0009
TO REDUCE THE RISK OF INJURY TO PERSON(S)
IN THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels –
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you
know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or
unbalanced impeller, keep drywall spray, construction dust,
etc. off power unit.
4. Do not use over cooking equipment greater than 60,000
BTU/hr. as the blower motor will shut down intermittently.
5. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated.
The motor will restart when it will cool down. If the motor
continues to shut off and restart, have the hood serviced.
6. The bottom of the hood MUST NOT BE LESS than 30" and
at a maximum of 36" above cooktop for best capture of
cooking impurities.
7. Two installers are recommended because of the size of
this hood.
8. To reduce risk of fire and to properly exhaust air, be sure
to duct air outside. Do not exhaust air into spaces within
walls or ceilings or into attics, crawl spaces, or garages.
9. Be careful when installing the decorative flue and hood, they
may have sharp edges.
10. Please read specification label on product for further
information and requirements.
MODEL B5936SS
.
!
VQ0009
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Broan B5936SS

  • Page 1: Range Hood

    MODEL B5936SS Page 1 CHIMNEY To register this product visit: www.broan.com RANGE HOOD READ AND SAVE THESE INSTRUCTIONS ntended for domestIc cookIng only VQ0009 VQ0009 WARNING WARNING VQ0009 VQ0009 TO REDUCE THE RISK OF FIRE, ELECTRIC TO REDUCE THE RISK OF INJURY TO PERSON(S)
  • Page 2: Install The Ductwork

    MODEL B5936SS Page 2 INSTALL THE DUCTWORK (Ducted Hoods Only) PREPARE THE HOOD Unpack hood and check contents. You should receive: ROOF CAP 1 - Hood 1 - Metal Canopy 6” ROUND DUCT 1 - Decorative Flue Assembly (2 pcs.)
  • Page 3: Install Ceiling Support

    MODEL B5936SS Page 3 PREPARE THE HOOD INSTALL CEILING SUPPORT 6” ROUND DUCTWORK CEILING (4) M4 x 8mm JOISTS PAN HEAD DAMPER / DUCT SHEET METAL CONNECTOR SCREWS CROSS FRAMING CEILING 1. Place the hood on flat surface with protection to insure the...
  • Page 4: Install The Hood

    MODEL B5936SS Page 4 INSTALL THE HOOD (Ducted Installation Only) 3. Attach the upper set of (4) angle brackets to the outside of the lower angle brackets according to dimension “H”. Use (8) M4 x 10mm (16) M4 x 10mm pan head machine screws and (16) M4 PAN HEAD serrated flange nuts (4 at each angle bracket connection).
  • Page 5 MODEL B5936SS Page 5 INSTALL THE HOOD (Non-Ducted Installation Only) NON-DUCT OPTION AVAILABLE ONLY IN THE U. S. POWER CABLE NON-DUCTED F R O N RECIRCULATION FILTER (8) M4 x 10mm NON-DUCT PAN HEAD 8 MOUNTING PLENUM MACHINE SCREWS (M4 x 8...
  • Page 6 MODEL B5936SS Page 6 3. Attach the upper set of (4) angle brackets to the outside of the lower angle brackets according to dimension “H”. Use (16) M4 x 10mm pan head machine screws and (16) M4 (8) M4 x 10mm serrated flange nuts (4 at each angle bracket connection).
  • Page 7 MODEL B5936SS Page 7 NON-DUCT FILTER MOUNTING TABS (8) M4 x 10mm PAN HEAD NON-DUCT METAL MACHINE RECIRCULATION LATCH SCREWS FILTER GREASE FILTERS 13. Remove the grease filters by pulling down the metal latch tab and tilting the filters downward to remove.
  • Page 8: Light Bulbs

    MODEL B5936SS Page 8 LIGHT BULBS MAINTENANCE Grease Filters Grease filters should be cleaned monthly. Remove grease LIGHT BULB filters by pulling down on the metal latch tab. This will COVER disengage the filter from the hood. Tilt the filter downward and remove.
  • Page 9: Service Parts

    MODEL B5936SS Page 9 SERVICE PARTS PART NO. DESCRIPTION QTY. S99527129 Decorative Upper and Lower Flues S99526974 Motor / Blower Assembly S99526975 Light Socket Assembly S99527010 Light Trim Ring / Lens Assembly S99526976 Push Button Assembly S97018029 Aluminum Grease Filters (pair)
  • Page 10 MODÈLE B5936SS Page 10 Pour enregistrer ce produit, visitez : HOTTE DE www.broan.com CUISINE À CHEMINÉE LIRE CES DIRECTIVES ET LES CONSERVER our usage domestIque seulement VQ0009 VQ0009 AVERTISSEMENT AVERTISSEMENT VQ0009 VQ0009 AFIN DE RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC OBSERVEZ LES CONSIGNES SUIVANTES AFIN ÉLECTRIQUE OU DE BLESSURES CORPORELLES,...
  • Page 11: Préparation De La Hotte

    MODÈLE B5936SS Page 11 POSE DU CONDUIT (Hottes avec conduit seulement) PRÉPARATION DE LA HOTTE Déballez la hotte et vérifiez le contenu de la boîte. Celle-ci doit CAPUCHON DE TOIT contenir les éléments suivants : 1 - Hotte CONDUIT ROND 1 - Capot en métal...
  • Page 12 MODÈLE B5936SS INSTALLATION DU SUPPORT Page 12 AU PLAFOND PRÉPARATION DE LA HOTTE (4) VIS À CONDUIT ROND DE TÔLE À TÊTE 15,2 CM (6 PO) SOLIVES CLAPET / CYLINDRIQUE RACCORD M4 x 8 MM DE CONDUIT TRAVERSE PLAQUE DE 1.
  • Page 13: Installation De La Hotte

    MODÈLE B5936SS INSTALLATION DE LA HOTTE Page 13 (Installation avec conduits seulement) Pour les plafonds de 3 m (10 pi) : Procurez-vous une ral- longe de conduit décoratif pour plafonds de 3 m (10 pi) (modèle FXN59SS) qui comprend (4) autres supports angulaires, (1) (8) VIS conduit décoratif supérieur plus long et la quincaillerie de montage.
  • Page 14 MODÈLE B5936SS Page 14 INSTALLATION DE LA HOTTE (Installation sans conduits seulement) L’OPTION POUR INSTALLATION EN RECIRCULATION OFFERTE UNIQUEMENT AUX ÉTATS-UNIS. D’ A LIMENTATION FILTRE DE F R O N T RECIRCULATION POUR INSTALLATION (8) VIS SANS CONDUIT MÉCANIQUES CAISSON À...
  • Page 15 MODÈLE B5936SS Page 15 3. Fixez l’ensemble de (4) supports angulaires à l’extérieur des supports angulaires du bas selon la dimension « H ». Utilisez (16) vis mécaniques à tête cylindrique M4 x 10 mm et (16) (8) VIS écrous à embase dentelée M4 (4 à chaque raccord d’angle).
  • Page 16: Filtres Àgraisses

    MODÈLE B5936SS Page 16 LOQUETS DE RETENUE DU FILTRE SANS CONDUIT FILTRES DE (8) VIS RECIRCULATION MÉCANIQUES LANGUETTE POUR À TÊTE MÉTALLIQUE INSTALLATION CYLINDRIQUE SANS CONDUITS M4 x 10 MM FILTRES À GRAISSES 13. Enlevez les filtres à graisse en tirant vers le bas sur leur languette métallique et en basculant les filtres vers le bas.
  • Page 17: Entretien

    MODÈLE B5936SS Page 17 AMPOULES ENTRETIEN Filtres à graisses Les filtres à graisses doivent être nettoyés une fois par mois. COUVERCLE DES Enlevez les filtres à graisse en tirant vers le bas sur la languette AMPOULES métallique de retenue. Le filtre se dégagera de la hotte.
  • Page 18: Pièces De Rechange

    MODÈLE B5936SS Page 18 PIÈCES DE RECHANGE N° DE N° DE REPÈRE PIÈCE DESCRIPTION QTÉ S99527129 Conduits décoratifs supérieur et inférieur S99526974 Ensemble moteur / ventilateur S99526975 Ensemble de socle d’ampoule S99527010 Ensemble d’anneau de finition / lentille d’éclairage S99526976...
  • Page 19 MODELO B5936SS Página 19 Para registrar este producto visite: CAMPANA DE www.broan.com ESTUFA DE CHIMENEA LEA Y GUARDE ESTAS INSTRUCCIONES ndIcada solamente Para cocInar en casa VQ0009 VQ0009 ADVERTENCIA ADVERTENCIA VQ0009 VQ0009 PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS PARA REDUCIR EL RIESGO DE LESIONES PERSONALES ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LAS...
  • Page 20: Prepare La Campana

    MODELO B5936SS Página 20 INSTALACIÓN DEL SISTEMA DE CONDUCTOS (Sólo campanas para sistemas con conductos) PREPARE LA CAMPANA Desempaque la campana y revise el contenido del paquete. Debe TAPA DE TECHO contener lo siguiente: 1 - Campana CONDUCTO REDONDO 1 - Dosel de metal DE 6 PULG.
  • Page 21 MODELO B5936SS Página 21 INSTALE EL SOPORTE PARA EL CIELO RASO PREPARE LA CAMPANA CONDUCTO REDONDO (4) TORNILLOS DE VIGAS DEL DE 6 PULG. (15.2 CM) CHAPA METÁLICA CIELO RASO CONECTOR DEL M4 x 8 MM REGULADOR DE DE CABEZA TIRO/CONDUCTO TRONCOCÓNICA...
  • Page 22: Instale La Campana

    MODELO B5936SS INSTALE LA CAMPANA Página 22 (Únicamente en instalaciones con conductos) Para cielos rasos de 10 pies (3 m): Compre una extensión de tubo de humos de 10 pies (3 m) (Modelo FXN59SS) que incluye (4) soportes de montaje en ángulo adicionales, (1) tubo de humos superior más largo y herrajes de montaje adicionales.
  • Page 23 MODELO B5936SS Página 23 INSTALE LA CAMPANA (Únicamente en instalaciones sin conductos) OPCIÓN DE SIN CONDUCTOS DISPONIBLE SOLAMENTE EN LOS E.E.U.U. CABLE ELÉCTRICO FILTRO DE F R O N T RECIRCULACIÓN PARA SISTEMAS (8) TORNILLOS DE SIN CONDUCTOS MÁQUINA M4 x...
  • Page 24: Cable Eléctrico

    MODELO B5936SS Página 24 3. Fije el conjunto superior de (4) soportes en ángulo a la parte exterior de los soportes de ángulo inferior, de acuerdo con la dimensión “H”. Use (16) tornillos de máquina M4 x 10 mm de (8) TORNILLOS cabeza troncocónica y (16) tuercas de reborde serrado M4...
  • Page 25 MODELO B5936SS Página 25 LENGÜETAS DE MONTAJE DEL FILTRO SIN CONDUCTO (8) TORNILLOS DE MÁQUINA FILTRO DE M4 x 10 MM PESTILLO RECIRCULACIÓN DE CABEZA METÁLICO PARA TRONCOCÓNICA SISTEMAS SIN CONDUCTOS FILTROS DE GRASA 13. Retire los filtros de grasa estirando hacia abajo la cejilla metálica e inclinando los filtros hacia abajo para quitarlos.
  • Page 26: Mantenimiento

    MODELO B5936SS Página 26 BOMBILLAS MANTENIMIENTO Filtros de grasa Los filtros de grasa deben limpiarse una vez al mes. Retire los CUBIERTA DE LA filtros de grasa estirando hacia abajo le cejilla metálica. Esto BOMBILLA DE LUZ desprenderá el filtro de la campana. Incline el filtro hacia abajo y quítelo.
  • Page 27: Piezas De Servicio

    DIAGRAMA DE CABLEADO Alto Bajo Med. Alto Lámpara É HALÓGENO BOTÓN SALIDA NEGRO ENTRADA VER. NEGRO TRANSFORMADOR CAPACITOR 120V Bl G 120V 100W É AL MOTOR En nuestro sitio Web se pueden hacer los pedidos de las piezas de repuesto: www.broan.com...
  • Page 28 IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.

Table of Contents