Upgrading The Software - Sharp LC-60LE830E Service Manual

Lcd colour television
Hide thumbs Also See for LC-60LE830E:
Table of Contents

Advertisement

LC-60LE635E(B),RU(B)/636E(B),S(B)/638E(B)
12. Initialization to factory settings
CAUTION: When the factory settings have been made, all user setting data, including the channel settings, are initialized.
(The adjustments done in the adjustment process mode are not initialized.) Keep this in mind when initializing these settings.
A
d
u j
t s
m
e
n
i t
e t
m
1
Factory settings
After adjustments, exit the adjustment process mode.
To exit the adjustment process mode, unplug the AC power cord from the outlet to forcibly turn off the power.
When the power is turned off with the remote control, unplug the AC power cord and plug it back in (wait approximately 20 seconds before plugging
in the AC power cord).
After completing the NET connection., execute the NET initialization (Record of the server access).
Please execute the initialized in the factory setting again when you turn on the power supply after the initialized in the factory setting is set.

13. Upgrading the software

1. Turn on the AC power.
2. Insert the upgrading USB flash memory for upgrade into the service slot.
(After a while, an external input changes into USB automatically.)
3. Use the Menu button and cursor keys ( / /
- USB update on OSD menu.
4. The message (Insert the USB memory device contains the software update file) shows up.
Push OK when if there is no problem.
A
d
u j
t s
m
e
t n
c
o
n
d
t i
o i
n
s
Ends by turning off the
[Factory setting with adjustment process mode]
MAIN POWER key.
(See to below caution)
When succeeding: Background color (green)
When failing: Background color (red)
The following items are initialized in the factory setting.
1) User settings
2) Channel data (e.g. broadcast frequencies)
3) Maker option setting
4) Password data
/
), Ch keys (
[Information
Software update
Insert the USB memory device containing
the software update file.
ENTER:Enter
A
d
u j
t s
Enter the adjustment process mode.
Move the cursor to [INDUSTRY INIT] on page 2/20.
Use the R/C key to select a region from [EUROPE/RUSSIA/SWEDEN] and
press the [OK] key.
"EXECUTING" display appears.
After a while, "SUCCESS" display appears, the setting is completed.
/
) of R/C or on the set to select Menu - Setup - Information - Software update
USB update]
OK
5 – 19
m
e
t n
p
o r
c
e
d
u
e r

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents