Alarm
The control panel has an audible buzzer and an alarm indicator light
Indicators*
(Row 4) that turns on when an alarm is triggered. In addition, the
control panel will flash the following codes when an alarm is triggered:
Alarm Code
What it means
P1, P3
Probe Failure
HA
The temperature
inside the cellar is
too warm (>70°F for
more than 1 hour)
HA2
The condenser
temperature is too
high (above 140°F for
2 hours)
LA2
The temperature at
the condenser coils
(outside the cabinet)
has dropped below
the alarm
temperature setting
* Please note: the HA and LA alarms are disabled during the first 23 hours of operation after
the cooling unit is plugged in and/or turned on.
Optional
Protection
Mechanism
P3 > 132°F for more
than 2 hours
Alarms
What to do
Call CellarPro at 877.726.8496
Check seals;
Check if door was left open;
Lower the ambient temperatures
Check for appropriate installation, ventilation,
ambient conditions and cooling capacity
Clean the condenser coils and/or replace the
air filter;
Check for obstructions to the intake and/or
exhaust vents;
Check that the condenser fan is operating
Call CellarPro at 877.726.8496
Optional Protection Mechanism
CellarPro cooling systems can be programmed to turn off the
compressor and condenser fan in the event of an HA2 alarm,
as described below. If you'd like to turn on this protection
mechanism, please call us toll-free at 877.726.8496
The condenser probe is
measuring temperatures
that are too hot
The compressor and condenser
fan will turn off until the condenser
temperature falls below 120°F
-22-