Advertisement

CANOPY HOOD
INSTRUCTION MANUAL
Models 4799000 and 7099000
Product designs are subject to change without notice
© 1994, 2007 Labconco Corporation
4809400 Revision C / ECO E427
Printed in U.S.A.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4799000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Labconco 4799000

  • Page 1 CANOPY HOOD INSTRUCTION MANUAL Models 4799000 and 7099000 Product designs are subject to change without notice © 1994, 2007 Labconco Corporation 4809400 Revision C / ECO E427 Printed in U.S.A.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction Components Shipped General Description Performance Installation Safety Precautions Dimensions Warranty & Contacting Labconco...
  • Page 3 PREFACE Thank you for displaying confidence in us by selecting a Labconco Canopy Hood. Our design engineers, assemblers and inspectors have utilized their skills and years of experience to ensure that the new Labconco Canopy Hood meets our high standards of quality and performance.
  • Page 4: Components Shipped

    INTRODUCTION Components Shipped Carefully check the contents of the carton for damage that might have occurred in transit. Do not discard the carton or packing material until all components have been checked against the following component list and the equipment has been installed and tested. As shipped, the carton should contain the following: Part Number Description...
  • Page 5: General Description

    INTRODUCTION General Description The Labconco Canopy Hood is designed for special purpose functions in which heat, steam or odors are generated. Large or bulky apparatus such as tissue processor, steam baths or open Kjeldahls can be used in conjunction with the Canopy Hood. The epoxy-coated superstructure has an integral baffle to increase slot velocities and enhance the overall capture efficiency of the hood.
  • Page 6: Installation

    INSTALLATION The most effective installation is one in which the back is mounted against a wall while the front is supported by 3/8 inch threaded rod mounted to the ceiling. Wire or cable may be substituted for the 3/8 inch threaded rod. Please see Figure 1 for recommended installation technique. Figure 1 Hood Efficiency The Canopy Hood can be extremely effective when installed correctly.
  • Page 7 INSTALLATION Figure 2...
  • Page 8: Safety Precautions

    SAFETY PRECAUTIONS Note: Canopy Hoods are not provided with explosion proof electrical components. Flammable or explosive atmospheres should not be used in conjunction with this hood.
  • Page 9: Dimensions

    DIMENSIONS...
  • Page 10: Warranty & Contacting Labconco

    Contacting Labconco Corporation If you have questions that are not addressed in this manual, or if you need technical assistance, contact Labconco’s Customer Service Department or Labconco’s Product Service Department at 1-800-821-5525 or 1-816-333-8811, between the hours of 7:00 a.m. and 6:00 p.m., Central Standard Time.

This manual is also suitable for:

7099000

Table of Contents