Fresh Water System - Jayco 2016 Melbourne Owner's Manual

Table of Contents

Advertisement

p
S
lumbing
yStem
Operation
Press only one "tact" switch at a time. As you push either the "FRESH", "BLK" "GREY1"
or "GREY2" switch, one or more LED lights will illuminate (from left to right) indicating
the content level for that tank. When pushing the "BATT" switch, the LED lights illuminate
from left (lowest) to right (highest) to indicate the estimated auxiliary battery condition.
NOTE: When using shore power all 4 LEDs will light. If discon-
nected from shore power, 3 LEDs will light to indicate a full charge.
(The 4th LED may blink)
The LEDs corresponding to the letters C,G,F,L on the panel indicate the following:
C
=
Charge at 12.7 volts
G
Good at 12.1 volts
=
F
=
Fair at 11.6 volts
L
=
Low at 6.0 volts.
Water pump switch (if so equipped)
The red water pump switch is located on the monitor panel, the utility center or both
(depending on your model). When the water pump switch is ON, the water pump will run
until it reaches 45 lbs. of pressure. It will recycle when pressure drops. The switch will light
up when it is turned ON. Turn the switch OFF when the water pump is not being used.
Water heater switches (if so equipped)
These red switches are located on the monitor panel. The "LP GAS" water heater switch
(12V) enables propane operation of the water heater. The "ELECTRIC" water heater switch
(120V) enables electric operation of the water heater. Normally both switches should be
turned on to provide the fastest hot water recovery time. The water heater can be operated
in electric only or gas only modes by pressing each switch independently. The switches will
light up when turned ON. If the RV contains a tankless water heater, these switches will not
be present on the monitor panel.
DSI FLT - Direct Spark Ignition Fault (if so equipped): This light located between the
water heater switches will indicate a problem with the LP portion of the water heater. When
the LP GAS switch is turned on, the light will blink quickly 3 times and the water heater will
ignite. The light will then remain off. If the light comes on and stays on, it indicates the gas
side of the water heater has not fired and there is a problem with the igniter.
f
W
resh
Ater
All water contains contaminant and mineral particles that can cause fresh water system
odors. Untreated well water is a major source of water system odors. The fresh water (or
potable water) system needs periodic sanitization and winterization to take care of all the
components within the plumbing system and help discourage the growth of bacteria and
other organisms that can contaminate the water supply.
DO NOT drink water deemed microbiologically unsafe or of unknown quality..