Optional Mantel Installation - Desa CDCFPRA Operation And Installation Manual

Unvented (vent-free) gas compact classic hearth® dual burner fireplace
Table of Contents

Advertisement

iNsTallaTioN
Continued
NOTICE: If your installation does
not meet the minimum clear-
ances shown in Figure 10, you
must do one of the following:
• raise the mantel to an accept-
able height
• remove the mantel
10"
Note:
8"
A ll vertical
measurements
6"
are from top of
2
fireplace
opening to
bottom of
mantel shelf. All
measurements
are in inches.
Figure 10 - Minimum Mantel Clearances
for Built-In Installation

OPTIONAL MANTEL INSTALLATION

Refer to instructions provided with the mantel
for assembly instructions. Refer to the follow-
ing instructions for system installation. Refer to
instructions on page 6 for hood assembly. Blower
accessory should be installed prior to mantel if
it is being used (see Installing Optional Blower
Accessory GA3450TA, page 13).
1. Assemble cabinet mantel as shown in acces-
sory instruction sheet.
2. If blower is installed, install a properly
grounded, 120 volt three-prong electrical out-
let at fireplace location if an outlet is not there.
If possible, locate outlet so cabinet mantel will
cover it when installed (see Figure 11).
3. Place hearth base against wall at installation
location. Cut an access hole in hearth base to
run gas line to fireplace (see Figure 11). Make
sure to locate access hole so cabinet mantel will
cover it when installed. Note: You can secure
base to floor using wood screws. Countersink
screw heads and putty over.
1
Mantel Shelf
1
/
"
2
Side of Firebox
www.desatech.com
4. Route flexible gas line through access hole in
hearth base.
5. Center cabinet mantel on hearth base (see
Figure 12). Make sure mantel is flush against
wall and centered left to right on base.
6. Use screws provided with mantel accessory
to attach mantel assembly to base (see mantel
instruction sheet).
7. Attach flexible gas line to fireplace gas regula-
tor. See Connecting to Gas Supply, page 16.
8. Route electrical cord(s) through access holes
in either side of fireplace with bushing. Plug
electrical cord(s) into electrical outlet.
9. Check all gas connections for leaks. See
Checking Gas Connections, page 17.
10. Carefully insert fireplace into cabinet mantel
(see Figure 13, page 13). Be careful not to
scratch or damage hearth base or cabinet
mantel.
11. Place metal trim on shoulder screws located
on the side and to of the fireplace (see Assem-
bling Perimeter Trim on page 13). Firmly snap
trim over shoulder screws. Align fireplace in
mantel assembly so the trim overlaps mantel
evenly on all three sides.
Pipe and Gas
Hearth
Shutoff Valve
Base
Figure 11 - Placing Hearth Base Against Wall
Cabinet
Mantel
Hearth
Base
Figure 12 - Installing Cabinet Mantel onto
Hearth Base
Electrical
Outlet
116658-01D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdcfnra

Table of Contents