Local Codes; Product Features; Unpacking; Hood Assembly - Desa CDCFPRA Operation And Installation Manual

Unvented (vent-free) gas compact classic hearth® dual burner fireplace
Table of Contents

Advertisement

loCal CoDEs

Install and use fireplace with care. Follow all local
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269

pRoDUCT FEaTUREs

SAFETY PILOT
This fireplace has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free room
fireplaces. The ODS/pilot shuts off the fireplace if
there is not enough fresh air.
PIEzO IGNITION SYSTEM
This fireplace has a piezo ignitor. This system
requires no matches, batteries, or other sources
to light fireplace.

UNpaCkiNG

WARNING: Ceramic brick
liners are located behind upper
louver and must be removed
before lighting fireplace.
1. Remove fireplace and hood from carton.
Log is wrapped and inside fireplace. Do not
remove at this time.
2. Remove all protective packaging applied to
fireplace for shipment.
3. Make sure your fireplace includes one hard-
ware packet.
4. Check fireplace for any shipping damage. If
fireplace is damaged, promptly inform dealer
where you bought fireplace.
116658-01D
REMOvING CERAMIC bRICK
LINERS
1. Remove screws from top louver and carefully
remove louver (see Figure 2).
2. Remove ceramic brick liners with protective
packaging. The brick liners will be installed
later.
3. Remove yellow sticker from top of firebox.
4. Replace top louver using screws removed in
step 1.
Wrapped
Brick Liners
Top Louver
Figure 2 - Removing Brick Liners
screen in place before operating
fireplace. This prevents exces-
sive temperatures on fireplace
surfaces.
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this fireplace may result in prop-
erty damage or personal injury.
Tools Required:
• Phillips screwdriver
• 5/16" hex wrench
1. Cut two plastic straps to remove the log from
the firebox cavity. Set log aside.
2. An optional blower is available. See Acces-
sories, page 38. Install optional blower now.
Follow installation instructions provided with
blower and see page 14 or 15, depending on
your installation.
www.desatech.com
Screws

HooD assEmBly

WARNING: Always have
• slotted screwdriver
• scissors
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdcfnra

Table of Contents