Remote Controller Display; Operation Lamp - Mitsubishi Electric PL42FK21 Service Manual

Table of Contents

Advertisement

Remote controller display

CENTRALLY
CONTROLLED display
This indicates when the unit is con-
trolled by optional features such as
central control type remote controller.
display
TIMER
This indicates when the continuous
operation and time operation modes
are set.
It also display the time for the timer
operation at the same time as when
it is set.
OPERATION MODE display
This indicates the operation mode.
display
CHECK
This indicates when a malfunction
has occurred in the unit which should
be checked.
Caution
Only the
display lights when the unit is stopped and power supplied to the unit.
When power is turned ON for the first time the (CENTRAL CTRL) display appears to go off momentarily but this is not a malfunction.
When the central control remote control unit, which is sold separately, is used the ON-OFF button,OPERATION MODE button and SET
TEMP . button do not operate.
"NOT AVAILABLE" is displayed when the AIR SWEEP button are pressed.
(AIR SWEEP function is not provided for PL series.)
CLOCK display
The current time , start time and stop
time can be displayed in ten second
intervals by pressing the time switch
button. The start time or stop time is
always displayed during the timer
operation.
SWING
DRY COOL
TIMER OFF TIMER
CLOCK AUTO AUTO
FAN
FAN
CHECK SET TEMP.
START STOP
SPEED
MODE
TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FILTER
SET TEMP.
TIMER SET
REMOTE CONTROLLER
PAR-JC240KUS
display
F
This displays the selected setting
temperature.
OC194-5
In this display example on the bottom left, a condi-
tion where all display lamps light is shown for
explanation purposes although this differs from
actual operation.
AIR DISCHARGE display
This displays the air direction.
F
AUTO
RETURN
AIR SWEEP
CHECK
TEST RUN
display
This lamp lights when electricity is
supplied to the unit.
FAN SPEED display
The selected fan speed is displayed.
display
F
The temperature of the return air is
displayed during operation. The dis-
play range is 47°F to 97°F. The dis-
play flashes 47°F when the actual
temperature is less than 47°F and
flashes 97°F when the actual tem-
perature is greater than 97°F.

Operation lamp

This lamp lights during operation,
goes off when the unit stops and
flashes when a malfunction occurs.
CHECK MODE
display
TEST RUN
This display lights in the check mode
or when a test operation is per-
formed.
display
FILTER
This lamp lights when the filter needs
to be cleaned.