Air-conditioners for building application
Hide thumbs Also See for PLFY-WP VBM-E:

Advertisement

Quick Links

Air-Conditioners For Building Application

INDOOR UNIT

PLFY-WP·VBM-E

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil exté-
rieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
.
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
(RU)

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PLFY-WP VBM-E

  • Page 1: Indoor Unit

    Air-Conditioners For Building Application INDOOR UNIT PLFY-WP·VBM-E INSTALLATION MANUAL FOR INSTALLER English (GB) For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch (D) Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie- nungsanleitung und das Installationshandbuch gründlich durchlesen.
  • Page 2: Table Of Contents

    Contents 1. Safety precautions ..................2 5. Electrical work ...................7 2. Installing the indoor unit ................2 6. Installing the grille ..................11 3. Connecting drain pipe ................4 7. Test run ....................14 4. Connecting water pipes ................5 Note: The phrase Wired re ote controller in this installation anual re ers onl to the PAR- 2MAA ou need an in or ation or the other re ote controller please re er to either the installation anual or initial setting...
  • Page 3 2 Installing the indoor unit 2 2 Ceiling openings and suspension olt installation locations (Fig 2-2) 950 D Caution: 20-45 860-910 C 20-45 810 B Install the indoor unit at least 2 a o e oor or grade le el Using the installation template (top of the package) and the gauge (supplied as an accessory with the grille), make an opening in the ceiling so that the main unit can be installed as shown in the diagram.
  • Page 4: Connecting Drain Pipe

    2 Installing the indoor unit Unit suspension procedures (Fig 2- ) A Suspension bolt B Ceiling Suspend the main unit as shown in the diagram. C Nut Figures given in parentheses represent the dimensions in case of installing optional D Washer (with insulation) multi function casement.
  • Page 5: Connecting Water Pipes

    Connecting ater pipes Please observe the following precautions during installation. Hold the pipe on the unit side in place with a spanner when installing the pipes or I portant notes on ater pipe or installation strainer. Tighten screws to a torque of 4 N m. If there is a risk of freezing, carry out a procedure to prevent it.
  • Page 6 Connecting ater pipes 9. HBC water pipe connection sizes Water pipework is screw connections Connection size Pipe size Water Unit model Water Water Water Water volume ( ) inlet outlet return PLF -WP32 BM Inner Inner Rc 3 4 Rc 3 4 PLF -WP4 diameter diameter...
  • Page 7: Electrical Work

    Electrical Indoor unit (Fig 1. Remove the electrical wiring service panel. 2. Remove the electrical box cover. 3. Remove the MA Remote controller terminal cover. 4. Wire the power cable and control cable separately through the respective wiring entries given in the diagram. Do not allow slackening of the terminal screws.
  • Page 8 Electrical Minimum wire thickness (mm²) Local switch (A) Breaker for wiring Total operating current of the indoor unit Ground-fault interrupter *1 (NFB) Main cable Branch Ground Capacity Fuse 16 A or less *2 2 A current sensitivity *3 25 A or less *2 3 A current sensitivity *3 32 A or less *2 4 A current sensitivity *3...
  • Page 9 Electrical Connecting re ote controller indoor and outdoor trans ission ca les (Fig M1 M2 M1 M2 M1 M2 TB15 TB5 TB15 Connect indoor unit TB5 and outdoor unit TB3. (Non-polarized 2-wire) The “S” on indoor unit TB5 is a shielding wire connection. For speci cations about the connecting cables, refer to the outdoor unit installation manual.
  • Page 10: Electrical Characteristics

    Electrical 8 Electrical characteristics Symbols: MCA: Max. Circuit Amps ( 1.25×FLA) FLA: Full Load Amps IFM: Indoor Fan Motor Output: Fan motor rated output Power supply Model olts Hz Range - 1 MCA (A) Output (kW) FLA (A) PLFY-WP32 BM-E Max.: 264 PLFY-WP4 BM-E...
  • Page 11: Installing The Grille

    Installing the grille Chec ing the contents (Fig This kit contains this manual and the following parts. Accessory name Q’ty Remark Grille 95 × 95 (mm) Screw with captive washer M5 × . × 25 Gauge (Divided into four parts) Fastener Screw 4 ×...
  • Page 12 Installing the grille Installing the grille Preparations (Fig A Main unit B Screw with captive washer Install the 2 enclosed screws with washer 2 in the main unit (at the corner drain pipe area and at the opposite corner) as shown in the diagram. 2 Te porar installation o the grille (Fig Temporarily secure the grille using the bell shaped holes by putting the socket of the grille marked G on the corner drain pipe area of the main unit.
  • Page 13 Installing the grille Installing the inta e grille (Fig Note: When reinstalling the corner panels (each ith a sa et ire attached) con- nect the other end o each sa et ire to the grille using a scre ( pcs ×...
  • Page 14: Test Run

    Test run Be ore test run A ter co pleting installation and the iring and piping o the indoor and Do not touch the s itches et ngers outdoor units chec or re rigerant lea age looseness in the po er suppl - Touching a switch with wet ngers can cause electric shock.
  • Page 15 Test run Step S itch the re ote controller to Test run 1 Select “Service” from the Main menu, and press the button. 2 When the Service menu is selected, a window will appear asking for the password. (Fig. 7-3) To enter the current maintenance password (4 numerical digits), move the cursor to the digit you want to change with the button, and set each number ( through 9) with the...
  • Page 16 ...............72 ................77 ............72 ............ 81 ............74 .................84 .............. 75 PAR- 32MAA “ ” Mitsu ishi Electric (10 20 (Fig 2-1) ( 5 × 25) Fig 2-1...
  • Page 17 (Fig 2-2) 950 D 20-45 860-910 C 20-45 810 B Fig. 2-2, 187,5 840 A 10 (3/8 ). . 1500 Fig 2-2 32, 40, 50 (Fig 2-3) Fig. 2-3. 120° ø175 3-ø2,8 ø125 ø100 Fig 2-3 14-ø2,8 ø150 ) (Fig 2-4) 100-150 10 (3/8 ) ( 10 (3/8 ).
  • Page 18 (Fig 2-5) Min. 30 . 30 17-22 . (Fig. 2-6) Fig 2-5 Fig 2-6 (Fig 2-7) Fig 2-7 (Fig 3-1) Ma c. 20 Max. 20m VP25 (O.D. ø32 PVC TUBE) 1,5–2m 1,5–2 1/100 Ma c. 15 Max. 15cm (1/100 ø D O.
  • Page 19 40 · . [145 HBC. HBC, 5102. HBC. HBC ( [Fig.4-1] Fig 4-1 Fig 4-2...
  • Page 20 PLFY-WP32VBM PLFY-WP40VBM Rc 3/4 Rc 3/4 PLFY-WP50VBM Fig 4-3 . 4-4] 1 mg/ . Fig 4-4 [20<T<60°C] pH (25°C) 7,0 ~ 8,0 7,0 ~ 8,0 (mS/m) (25°C) [300 [300 ( s/cm) (25°C) (mg Cl-/ ) 50 (mg SO4 -/ ) 50 (pH4,8) (mg CaCO / ) 50...
  • Page 21 (Fig 5-1) ) (L, N, (M1, M2, S) (1, 2) 60245 IEC 53 60227 IEC 53. Fig 5-2 Fig 5-1 M1 M2 S TB15 Fig 5-2...
  • Page 22 ²) F0 = 16 A 20 A *3 F0 = 25 A 30 A *3 F0 = 32 A 40 A *3 IEC61000-3-3. “F0” “F1” “F2”. F1 = × 1,2 F2 = {V1 × ( 1)/C} + {V1 × ( 2)/C} + {V1 ×...
  • Page 23 M1 M2 M1 M2 M1 M2 TB15 TB5 TB15 (Fig 5-3) “S” 0,75 10 , M1 M2 M1 M2 M1 M2 1,25 “MA” “1” “2” TB15 “MA”. ( 9 - 13 “MA”) “M-NET” “M1” “M2” “M-NET”. ( 24 - 30 “M-NET”) CN90 CN90...
  • Page 24 (= 1,25× ( )/ +- 10% PLFY-WP32VBM-E 0,44 0,05 0,35 .: 264 PLFY-WP40VBM-E 0,44 0,05 0,35 220-240 / 50 .: 198 PLFY-WP50VBM-E 0,57 0,05 0,45 PLFY-BM “ ” – MITSUBISHI “ ” - ELECTRIC : “0” “M-NET address” ( “Maintenance” ( Manual vane angle Main Main menu...
  • Page 25 (Fig 6-1) 950 × 950 ( M5 × 0,8 × 25 4 × 8 4 × 12 i-see sensor PLP-6BAE Fig 6-1 (Fig 6-2) : 860 × 860 - 910 × 910 17-22 Fig 6-2 6 2 1 (Fig 6-3) “...
  • Page 26 6 4 1 (Fig 6-5) Fig 6-5 6 4 2 (Fig 6-6) 6 4 3 (Fig 6-7) Fig 6-6 6 4 4 (Fig 6-8) , 20- Fig 6-7 Fig 6-8...
  • Page 27 (Fig 6-9) 4 × 8) “6.2. ”. (4 × 8) 5 Fig 6-9 CN4Y CN6Y i-see sensor 7 H i-see sensor ( PLP-6BAE) i-see sensor (Fig 6-10) PLP-6BAE CN4Y( CN6Y( i-see sensor 7 i-see sensor 7 Fig 6-10 i-see sensor “6.2.
  • Page 28 500- 7 2 1 HBC. 7 2 2 (Fig 7-1) : 1,3 ± 0,3 · ) Fig 7-1 7 3 1 (Fig 7-2) Fig 7-2...
  • Page 29 Test run ( “Service” ( . (Fig. 7-3) “9999” (“9999”) “Test run” ( . (Fig. 7-4) “Test run” ( . (Fig. 7-5) Service menu Test run menu Test run Test run Enter maintenance password Input maintenance info. Drain pump test run Function setting Check Self check...
  • Page 30 This product is designed and intended for use in the residential, commercial and light-industrial environment. Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN BH79D500K02 Printed in UNITED KINGDOM...

Table of Contents