Service Menu Content - Asko WM70.C Service Manual

Professional
Hide thumbs Also See for WM70.C:
Table of Contents

Advertisement

Service manual WM70.C

Service menu content

1 Service
11 Info
12 Fault
scenarios
13
Diagnostics
14 Total
reset
15 ABC
reset
Return
2 Settings
21 Water
inlet
22 Max
RPM
23 Drain
17
SP: XXXX
Date the software was programmed (Year_Week)
CM: XXXX
Date of manufacture of the control unit (Year_
Week)
SW:
Software version
SW:
Software version
NC:
Number of cycles/programmes run
NC 1:
Number of cycles for Programme 1
NC 2:
Number of cycles for Programme 2
NC 3:
Number of cycles for Programme 3
NC 4:
Number of cycles for Programme 4
NC 5:
Number of cycles for Programme 5
NC 6:
Number of cycles for Programme 6
NC 7:
Number of cycles for Programme 7
NC 8:
Number of cycles for Programme 8
NC 9:
Number of cycles for Programme 9
NC 10:
Number of cycles for Programme 10
Fault 1
Shows current fault. The display shows Fault
name_Programme number_Number of cycles_
Fault 2
Index number.
Example: Thermistor fault_Pr5_9_(1)
Fault 3
Error messages are erased from the system during
a total reset.
Test
Test valve 1
Inlet valve 1 is open.
Test valve 2
Inlet valve 2 is open.
Test valve SM
Inlet valve 1 and 2 are open.
Test valve 3
Inlet valve 3 is open.
Test heater
Heater on up to max. 60°C.
Test motor
The motor normally runs at 49 rpm.
Test drain
The drainage pump runs.
Test spin
The machine runs a spin sequence, the drainage
pump runs.
Test door
The door lock is activated and the door opens.
Returns to the programme menu.
The machine is restored to its factory settings.
Returns to the programme menu after Total reset.
The custom programmes (Pr20-Pr22) are reset.
Returns to the programme menu after ABC reset.
Press the Key button (S5) to return to 1 Service.
Cold
Hot
400 rpm
This function only works for programmes
Pr1-Pr19.
600 rpm
800 rpm
1000 rpm
1200 rpm
1300 rpm
1400 rpm
1500 rpm
1600 rpm
Pump
Valve

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents