Table of Contents General • ........... Page 20 Delivery, Packaging, Recycling......20 Instructions for the installer Heater Positioning and Installation • ..21 Procedures to be followed........21 Choosing the Heater Position ......21 Assembly..............21 - Minimum Clearances .........21 - Tilting Safety, Wall Fixing ........21 - Heater assembly..........
To facilitate transport and handling, the heater cabinet (with built-in heating elements) and the bricks are packaged separately. The packaging of your high-quality Olsberg Appliance has been limited to the minimum necessary for safe transport and is made entirely of recyclable materials.
All National and Local Safety Codes should be ad- Tilting Safety, Wall Mounting hered to both at the planning and installation stages. Olsberg electric storage heaters must be protected against tipping over. To do this, the heaters are to be fixed to the wall.
Page 5
Heater Dim. H Dim. A 14/534 14/536 1056 Fig.1 Wall Mounting...
Heater assembly • Opening the heater (Fig.2): 1. Prise off the plastic caps and remove the screws. 2. Pull the side panels at the front outwards and remove them backwards. 3. Lift the top panel (A) approx. 10mm. 4. Pull the top panel forwards. 5.
Page 7
9. Remove the top front panel with both top front insulations. Fig.4 Remove the top front panel • Only for heater 14/534: Insert the channelled bricks using the guide plates provided, first the channelled bricks SP27, then the channelled bricks from SP26. You will find the number and type of storage brick packs in the sec- tion "Technical Data".
Page 8
• Pull the connection cords of the heating elements Outer upper insulation 10x270x505 completely through the openings prepared and Inner upper insulation bow the connection cords at the coloured bushes 15x242x455 carefully. Caution: Do not push the connection cords backwards to the interior. •...
Page 9
• Connect the heating elements to the charge control according to circuit diagram (page 28 Be careful that the capillary tubes do not touch live parts. • The heater is then re-assembled as described in Part 1-7 on page 23, but in reverse order. Disassembly of fan drawer For disassembly of drawer (e.g.
Electrical Connection The storage heater is connected to element feed (OFF-PEAK Tariff) and control cables for the room thermostat and the charge control (A1/Z1; A2/Z2). You will find the number and type of storage brick packs in the section "Technical Data" The heater is suitable for a direct cable feed, it is also suitable for feeding from a spur junction.
Circuit Diagram 78/4514.5361 Fitted components: Charge thermostat Storage heating elements Charge limiter Safety thermostat for fan Electric storage heater Fans Charge control resistance Fan compensatory resistance Terminal block current feed Terminal strip for power draw setting Power draw Terminal block for control cables The terminal strip X2 can be found on the inner side panel on the left side of the heater.
Rating Label The specific technical data for each heater are printed on the rating label. You can find the rating label at the below the air-outlet grille on the right hand side of the heater. Type Weight Charge circuit Discharge circuit The power ratings not connected are to be covered on the heater rating label using the grey coloured plain labels supplied.
Accessories Thermal Switching Relay Charge Control By installing a thermal switching relay into each stor- The charge control registers the outside temperature age heater, the Utility relays in the junction box can be and converts this value into a control current. This omitted.
Commissioning the Heater Trouble Shooting Tips Following tests must be carried out before com- Olsberg Storage heaters are equipped with a continu- missioning the heater: ous running charge control and a charge safety non- resetting limit switch. If the charge control does not •...
Instructions for the user Operation Energy saving tips The heater operation takes place by means of the • Only heat when necessary. recessed operating knob at the top right of the heater. • Keep the room temperature at 20°C if possible. By pushing the knob lightly, it will emerge for opera- Each degree above 20°C increases the heating tion.
(including children), with reduced physical, sensory or mental abilities or for lack of experience • Olsberg heaters have been constructed so that and/or for lack of knowledge to be used it by a per- they need only a minimum of maintenance.