SERVICE PROGRAM MODE
1
SP ADJUSTMENT
PAGE 9
û
ù
ÿ
Item
Inputs the exposure lamp voltage when
auto process control is disabled or RAM
is cleared (0.5 V/step).
Default: 65.0 V
Adjusts the transfer current for the 1st
side (1 µA/step).
Default: 40 µA (A175, A220)
50 µA (others)
Adjusts the transfer current for the 2nd
side (1 µA/step).
Default: 50 µA (A175, A220)
55 µA (others)
NOTE:
has been added for all the versions (A175/A176/A177/A191/
A192/A220).
A220 information has been added.
A220
Function
4-4
A220M502.img
Note
Enter the setting using the number keys,
%
then touch
and
Standard Data:
40 µA (A175, A220), 45 µA (others)
Enter the setting using the number keys,
then touch
.
Standard Data:
50 µA (A175, A220), 55 µA (others)
Enter the data by using the number keys,
then touch
.
.
SM