2.3 Wiring the Transceiver Unit

Except the power cable, all cables connected to the transceiver unit are factory-fitted connec-
tors.
Number inscribed
on sheath. Connect
wire according to
number.
Number affixed to cable
sheath. (Match number
with terminal number.)
How to fabricate power cable
Vinyl sheath
1
3
5
2
CN-B2
CN-B1
CN-B4
J6
J5
J7
-
+
TB-B1
KP signal I/O (video sounder, etc.)
Cable from hull unit
Cable from display unit
24 VDC
Ship's mains
40
5
100
Armor
Figure 2-4 Wiring in transceiver unit
Transducer cable
Cable clamp
4
6
Cable clamp
J1
P1
P3
J3
P2
J2
J9
J3 J4
CN-B3
TB-B1
White
Black
2-3
Ground at thin
metallic band
of cable.
Fasten wire
here.
+
-