Title
ClearPath HMP Enterprise Servers NX5820 and NX5820 K Hardware Configuration Guide
(7017 6300–005)
This guide is intended to assist individuals responsible for defining and configuring a Unisys ClearPath HMP
Enterprise Servers NX5820 and NX5820 K product with future expansion in mind. Guidelines and recommendations
to assist the individuals responsible for defining and configuring a Unisys ClearPath HMP Enterprise Server NX5820
and NX5820 K server are also provided. The following product lines are available:
ClearPath HMP Enterprise Server NX5821 models are single-domain systems containing a single
VX1305-BSE/BSU, VX1505-BSE/BSU, ES5085, ES2024, or ES5044 based server.
ClearPath HMP Enterprise Server NX5822 models are dual-domain systems containing a single
VX1305-BSE/BSU, VX1505-BSE/BSU, ES5085R, ES2024, or ES5044 based server with an optional server of
the same type.
Technical changes and additions were made to provide coverage for the ES2024R and ES5044R servers.
To order additional copies of this document, visit the online Unisys Book Store at one of the following URLs:
United States customers, call Unisys Direct at 1-800-448-1424.
Customers outside the United States, contact your Unisys sales office.
Unisys personnel, order through the electronic Book Store at http://iwww.bookstore.unisys.com.
Comments about documentation can be sent through e-mail to doc@unisys.com.
Announcement only:
Product Information
Announcement
o New Release
Announcement and attachments:
AS273, CSES, and ECCA
Revision
o Update
System:
ClearPath HMP Enterprise
Servers NX5820 and NX5820 K
Release:
Date:
June 2000
Part number: 7017 6300–005
o New Mail Code

Advertisement

Table of Contents
loading

Summary of Contents for Unisys NX5820 K

  • Page 1 Technical changes and additions were made to provide coverage for the ES2024R and ES5044R servers. To order additional copies of this document, visit the online Unisys Book Store at one of the following URLs: • United States customers, call Unisys Direct at 1-800-448-1424.
  • Page 2 white text to force blank page on duplex printerthese characters as “white” to force printing of blank page.
  • Page 3 ClearPath HMP Enterprise Servers NX5820 and NX5820 K Hardware Configuration Guide Printed in USA June 2000 7017 6300–005...
  • Page 4 Format these characters as “white” to force printing of blank page.
  • Page 5 ClearPath HMP Enterprise Servers NX5820 and NX5820 K Hardware Configuration Guide Unisys û 2000 Unisys Corporation. All rights reserved. Printed in USA June 2000 7017 6300–005...
  • Page 6 The only warranties made by Unisys, if any, with respect to the products described in this document are set forth in such agreement. Unisys cannot accept any financial or other responsibility that may be the result of your use of the information in this document or software material, including direct, special, or consequential damages.
  • Page 7 ClearPath HMP ClearPath HMP Enterprise Servers Enterprise Servers NX5820 and NX5820 K NX5820 and NX5820 K Hardware Configuration Hardware Configuration Guide Guide 7017 6300–005 7017 6300–005 Bend here, peel upwards and apply to spine.
  • Page 8 Format these characters as “white” to force printing of blank page.
  • Page 9: Table Of Contents

    Contents About This Guide ..................Section 1. Introduction How to Use This Guide ............1–1 What Product Models Are Covered ........1–2 System Architecture .............. 1–2 Features ..............1–2 Technology Enhancements ........1–2 System Partitioning ............... 1–3 Single Domain ............1–3 Dual Domain ............
  • Page 10 3–12 Configuration Guidelines for SCP Monitors and ODW Displays .............. 3–12 Work Space ................3–14 Redundant Power for the NX5820 and NX5820 K ....3–14 Configuring Additional OSS7000 Devices ......3–14 Converting From NX5820 to NX5820 K Systems ....3–14 Section 4.
  • Page 11 Contents Section 5. Configuring the Input/Output Module Introduction ................5–1 How This Section Is Organized ..........5–1 How the IOM Is Organized ............. 5–2 IOM Logical Organization .......... 5–2 IOM Physical Organization ........5–3 IOM Options ............5–5 CMF External Connectivity ........5–5 CIOM Upgrade ............
  • Page 12 Contents Configuration Guidelines ES5085R ......6–25 ES2024R Servers ..............6–26 Basic Features ............6–26 Server Components ..........6–28 Processors .............. 6–30 Memory Packages ........... 6–30 Connection Packages and Optional PCI ...... 6–31 Optional User Access Components ......6–32 Configuration Guidelines ES2024R ......6–32 ES5044R Servers ..............
  • Page 13 Figures 1–1. Typical View of ClearPath Enterprise Server NX5820 and NX5820 K with VX1505 (7U) Servers ................ 1–8 1–2. System Cabinet PCA Locations for NX5820 ..........1–9 1–3. System Cabinet PCA Locations for NX5820 K ......... 1–10 1–4. Block Diagram of ClearPath Enterprise Server NX5820 and NX5820 K Single-Domain, Single-Console Configuration ........
  • Page 14 Figures 5–8. Dual Domain Typical PCITHRU Card Location in the Internal and External Channel Racks .................. 5–15 5–9. PCITHRU Slot Versus PCI Bridge Jumper Positions ........5–16 6–1. Road Map for Ordering VX1305 Servers ..........6–4 6–2. VX1305 Server CS Bus Cable Connection ..........6–9 6–3.
  • Page 15 NX5820 K Dual Domain, Dual-Processor Multi-Processor Upgrades (DDMP) .................... 2–34 3–1. Basic Memory Board Configuration By System Style ........ 3–2 3–2. NX5820 and NX5820 K Memory Styles and Upgrade Components ... 3–2 3–3. Memory Card Slot Locations ..............3–9 3–4. Redundant System Console Package Styles ..........
  • Page 16 Tables 4–5. Configuring Power Net in Channel Racks ..........4–6 5–1. CMF External Connectivity Options ............5–6 5–2. Supported Channel Adapter Types ............5–7 5–3. CIOM CS-Bus Channel Loading ............... 5–8 5–4. Guidelines for Configuring Channels ............5–10 5–5. NX5820 Channel Assignments and Configurations ........5–12 6–1.
  • Page 17: About This Guide

    Purpose This guide provides: • Guidelines and recommendations to assist the individuals responsible for defining and configuring a Unisys ClearPath Enterprise Server NX5820 and NX5820 K server • Guidelines to ensure ease of future expansion and maximum throughput Scope This guide provides: •...
  • Page 18: How To Use This Guide

    About This Guide How to Use This Guide • Read the entire guide to familiarize yourself with the basic concepts it presents • Use it as a reference for configuring system components and system options • Use it to facilitate the ordering of system components Organization This guide consists of the following sections.
  • Page 19 ClearPath Enterprise Server NX5820 and NX5820 K Hardware Overview (7017 6284) Describes the hardware configuration and features of the NX5820 and NX5820 K system, including a brief overview of each of the major components. ClearPath Enterprise Server NX5600, NX5800, NX5820, and NX5820 K Site Planning Guide (7016 7010) Describes how to prepare the site for system installation.
  • Page 20 About This Guide ClearPath Enterprise Server NX5600, NX5800, NX5820, and NX5820 K Site Planning Checklist (7016 7028) Provides checklists and procedures required to prepare the site for system installation. ClearPath Enterprise Server NX Series with Windows NT Implementation and Operations Guide (8807 6542) Provides instructions to install software products and software configurations for the Operator Display Workstations (ODW) in a Windows NT environment.
  • Page 21 Adhering to the guidelines presented in this guide will enable you to correctly configure the system and place a client order. For placing client orders, also refer to the Unisys Configuration software system (UCON) used by sales support and salesperson to prepare and configure Unisys computer products.
  • Page 22: What Product Models Are Covered

    NX5820 PRODUCTS NX5821 models 31 through 71 Single-Domain, Single-Processor (SDSP) NX5822 models 32 through 78 Dual-Domain, Multiple-Processor (DDMP) NX5820 K PRODUCTS NX5821–BAS Single-Domain, Single-Processor (SDSP) with performance level 31 to 71 NX5822–BAS Dual-Domain, and Multi--Processor (DDDP and DDMP) with performance...
  • Page 23: System Partitioning

    System Partitioning System Partitioning Single Domain • Cannot be partitioned. • A single-domain system contains: − Its own power, cooling, and maintenance interface − Its own master clock Dual Domain Single Monolithic Partition • The combined domains function as a monolithic system. •...
  • Page 24: Hardware Overview

    Figure 1–3 shows PCAs located for the CEC for the ClearPath Enterprise Server NX5820 Figure 1–4 through Figure 1–6 show block diagrams of the ClearPath Enterprise Server NX5820 and NX5820 K in various configurations of domains, switching hubs, servers, and consoles.
  • Page 25: Expansion Sections

    Hardware Overview Expansion Sections The expansion sections house the following units: − Server A − Optional servers (up to five maximum per domain) − Up to two Maintenance LAN Hubs, unlimited switching (Public) Hubs, and up to two Apex Selector ST Switches −...
  • Page 26: Other I/O Devices

    System Cabinet Organization Other I/O Devices The I/O subsystem accommodates any other device that connects via a CS-bus interface and is qualified for use on the system, such as: • Standalone disks and tapes • Devices housed in migratory I/O cabinets •...
  • Page 27: Acronyms For System Components

    System Components Table 1–2. Acronyms for System Components Acronym Component Name NX582x-rp Enterprise Server models: (x = 1, single-domain; x = 2, dual- domain; r = performance level; p = number of PMs per system) Automatic Power Control ASIC Application specific integrated circuit Asynchronous transfer mode CIOM Common Input/Output module...
  • Page 28: Typical View Of Clearpath Enterprise Server Nx5820 And Nx5820 K With

    Server D Windows NT Server A Central Equipment Section The servers shown are typical of the servers that can be configured. 0670 Figure 1–1. Typical View of ClearPath Enterprise Server NX5820 and NX5820 K with VX1505 (7U) Servers 1–8 7017 6300–005...
  • Page 29: System Cabinet Pca Locations For Nx5820

    System Components Front View Rear View Impeller Impeller Impeller Impeller Cooling Domain 0 Domain 1 Domain 1 Domain 0 AC Inlet AC Inlet AC Inlet Operator Panel Power Channel Channel Channel Channel Channel Channel Inlet Console Console Redundant Redundant Console Console CIOM per domain is dedicated to IOU functionality.
  • Page 30: System Cabinet Pca Locations For Nx5820 K

    802.3 Ch CS Bus Direct CS Bus BaseT OSS7000 Remote Support DISK Ch TAPE Ch Maintenance LAN Hub MAINTLAN T27's FEEDTHRU 0701 Figure 1–4. Block Diagram of ClearPath Enterprise Server NX5820 and NX5820 K Single- Domain, Single-Console Configuration 1–10 7017 6300–005...
  • Page 31: Block Diagram Of Clearpath Enterprise Server Nx5820 And Nx5820 K In

    DISK Ch TAPE Ch CS Bus Direct CS Bus 802.3 Ch Domain 1 Bridge BaseT 0702 10/100 NT B Environment BaseT Figure 1–5. Block Diagram of ClearPath Enterprise Server NX5820 and NX5820 K in Dual- Domain, Single-Console Configuration 7017 6300–005 1–11...
  • Page 32: Block Diagram Of Clearpath Enterprise Server Nx5820 And Nx5820 K In Dual-Domain, Redundant-Console/Redundant Public Switch Configuration

    Domain 1 Bridge BaseT 10/100 NT B Environment BaseT BaseT Public Switch B SCP B System Terminal Switch 0703 Figure 1–6. Block Diagram of ClearPath Enterprise Server NX5820 and NX5820 K in Dual- Domain, Redundant-Console/Redundant Public Switch Configuration 1–12 7017 6300–005...
  • Page 33: Configuring System Hardware

    Section 2 Configuring System Hardware How This Section Is Organized This section contains the following information for the ClearPath HMP Enterprise Servers NX5820 and NX5820 K products: • Provides a summary list of hardware components, by model • Provides an overview of each model, including the system cabinet card profile and a...
  • Page 34: Clearpath Enterprise Server Nx5820 Product Models

    NX5820 Products • One to two memory storage units with 192 MB or 384 MB storage per domain depending on model • Single server containing its own processing modules, memory, and peripheral subsystem, with a dual-server per domain option Notes: 1.
  • Page 35: Nx5820 Product Configurations

    NX5820 Product Configurations NX5820 Product Configurations This subsection describes the NX5820 product configurations. ClearPath Enterprise Server NX5821 Single-Domain, Single- Processor (SDSP) Configurations Models 31 through 71 • Table 2–2 lists component styles for these models. • Figure 2–1 and Figure 2–2 show the hardware configurations for system cabinets containing VX1305- and VX1505-based servers, respectively.
  • Page 36 NX5820 Product Configurations Table 2–2. ClearPath Enterprise Server NX5821 Single-Domain, Single-Processor Configurations, Models 31 through 71 Component Description NX5821 Models Style MSA104-192 MSUA BD, 1 CHIPSET, 4 REQUESTER, 192 MB NX5820-PSB BASIC POWER SUPPLY COMPLEMENT BRM36-O BASIC 36U CABINET ASSEMBLY, STAND ALONE RM2-TRM APPEARANCE TRIM NX5800-FAS...
  • Page 37: Nx5820 Single-Domain System Cabinet Configuration With Vx1305

    NX5820 Product Configurations APC2 APC2 OSS7000 Peripheral Rack VX1305-BSU Server Position 5 VX1305-BSU Server Position 4 VX1305-BSU Server Position 3 Console (Primary) VX1305-BSU Server Position 2 VX1305-BSE Server Position 1 Central Equipment Server Expansion Section Section 0704 Figure 2–1. NX5820 Single-Domain System Cabinet Configuration with VX1305 Servers 7017 6300–005 2–5...
  • Page 38: Clearpath Enterprise Server Nx5822 Dual-Domain, Multi-Processor (Ddmp) Configurations Models

    NX5820 Product Configurations APC2 APC2 OSS7000 Peripheral Rack VX1505-BSU Server Position 3 VX1505-BSU VX1505-BSU Server Position 5 Server Position 2 Console (Primary) VX1505-BSU VX1505-BSE Server Position 4 Server Position 1 Server Expansion Central Equipment Server Expansion Section Section Section 0705 Figure 2–2.
  • Page 39: Through 78

    NX5820 Product Configurations Table 2–3. ClearPath Enterprise Server NX5822 Dual-Domain, Multi-Processor Models 32 through 72 Component Description NX5822 Models Style NX580131-MOD MODULE ASSY, SINGLE DOMAIN 31 (Includes Cooling, Power, ac Entry, Card Rack Modules) NX580232-CMP DOMAIN ‘1’ COMPONENTS 32 NX58312-PRM STYLE PROM, NX5820 31/32 NX582232-UDE FUNCTIONAL S/W, IP EMULATION NX5822-32...
  • Page 40: Clearpath Enterprise Server Nx5822 Dual-Domain, Multi-Processors

    NX5820 Product Configurations Table 2–3. ClearPath Enterprise Server NX5822 Dual-Domain, Multi-Processor Models 32 through 72 Component Description NX5822 Models Style One of: Single server: VX1305-BSE or Server (4U, 1-2 Processor Server) VX1505-BSE or Server (7U, 1-4 Processor Server) ES5085R or Server (7U, 1-8 Processor Server) ES2024R or Server (7U, 1-2 Processor Server)
  • Page 41 NX5820 Product Configurations Table 2–4. ClearPath Enterprise Server NX5822 Dual-Domain, Multi-Processors Models 73 through 78 Component Description NX5822 Models Style NX580273-CMP DOMAIN ‘1’ COMPONENTS 73 NX582278-UDE FUNCTIONAL S/W, IP EMULATION NX5822-78 Common Components NX58712-PRM STYLE PROM, NX5820-71/72 NX5821-CCC DOMAIN 0 CARD COMPLEMENT, CIOM (1 PM, 2 CIOM, 1 KIOB) NX5822-CC DOMAIN 1 CARD COMPLEMENT, CIOM (1 PM, 2...
  • Page 42: Nx5820 Dual-Domain Redundant System Cabinet Configuration, With

    NX5820 Product Configurations APC2 APC2 APC2 APC2 OSS7000 Peripheral Rack VX1305-BSU VX1305-BSU Server Position 10 Server Position 5 VX1305-BSU VX1305-BSU Server Position 4 Server Position 9 VX1305-BSU VX1305-BSU Server Position 8 Server Position 3 Console (Primary) VX1305-BSU VX1305-BSU Server Position 7 Server Position 2 Console VX1305-BSU...
  • Page 43: Nx5820 Companion Package Style

    NX5820 Product Configurations NX5820 Companion Package Style Table 2–5 summarizes the companion package styles required for the various NX5820 models. As noted in the component style charts, these package styles must be ordered separately from the system package style. Additional components may be added through system upgrades (see "System Upgrades") or through system options (see Section 3).
  • Page 44: Nx5820 K Products

    NX5820 K Products NX5820 K Products Table 2–6 lists the basic hardware components associated with each NX5820 K product model. The minimum and maximum system configurations are as follows: Single-Domain, Single-Processor (SDSP) NX5821 – BAS Models • Requires style NX5821-1D1 •...
  • Page 45: Dual-Domain, Multiple-Processor (Ddmp) Nx5822 - Bas Models

    NX5820 K Products Dual-Domain, Multiple-Processor (DDMP) NX5822 – BAS Models • Requires one of the following styles NX5822-2D3 to NX5822-2DA • Minimum system performance level – NX5823–PL7 (w/PROM NX58273-PRK) Maximum system performance level – NX58210–PL7 (w/PROM NX582710-PRK) • Three to ten processor modules (PM) depending on model •...
  • Page 46: Clearpath Enterprise Server Nx5820 K Product Models

    NX5820 K Products Table 2–6. ClearPath Enterprise Server NX5820 K Product Models Model Processor Memory CIOM Servers System SCSI-2W 802.3 Maint Maint Switching (Performance Modules Storage Modules Std/Max (SCP) Channels Channels Level) Units Std/Max Console Channel Std/Max Std/Max Std/Max NX5820 K Single-Domain, Single-Processor (SDSP) Models...
  • Page 47: Nx5820 K Product Configurations

    (with NX58210-PL7) Notes: The NX5820 K utilizes two styles of memory boards (MSA and MSK). The MSA104 boards are to be configured in all systems up to and including models NX5821-1D1 and NX5822-2D2. The MSK208 boards are to be configured in system models NX5822-2D3 to -2D6. The MSK412 boards are to be configured in models NX5822-2D7, NX5822-2D8 and -2DA.
  • Page 48: Clearpath Enterprise Server Nx5821-Bas Single-Domain, Single-Processor Configurations

    NX5820 K Product Configurations Table 2–7. ClearPath Enterprise Server NX5821–BAS Single-Domain, Single-Processor Configurations Package Style NX5821–BAS Component Style Description Qty. ADP68501-FTF 68F/50F SCSI ADAPTER B25-LC POWER CORD:LINE CORD BRM36-O BASIC 36U CAB ASSEMBLY, STAND ALONE BRM36-O2 BASIC 36U CAB ASSEMBLY, STAND ALONE...
  • Page 49 NX5820 K Product Configurations Table 2–7. ClearPath Enterprise Server NX5821–BAS Single-Domain, Single-Processor Configurations Package Style NX5821–BAS Component Style Description Qty. PCK104-SKB KEYBOARD PCK1-EXT CABLE, M TO F PS2 PCT1200-INT 1.2 GB QIC TAPE PWM1-PS2 MOUSE 2-BUTTON RM2-AP2 APC II 2U RM-MODULE...
  • Page 50: Nx5820 K Single-Domain System Cabinet Configuration With Vx1305 Servers

    Server Position 5 VX1305-BSU Server Position 4 VX1305-BSU Server Position 3 Console (Primary) VX1305-BSU Server Position 2 VX1305-BSE Server Position 1 Central Equipment Server Expansion Section Section 0704 Figure 2–5. NX5820 K Single-Domain System Cabinet Configuration with VX1305 Servers 2–18 7017 6300–005...
  • Page 51: Clearpath Enterprise Server Nx5822-Bas Dual-Domain Configurations

    Central Equipment Server Expansion Section Section Section 0705 Figure 2–6. NX5820 K Single-Domain Cabinet Configuration, with VX1505 Servers ClearPath Enterprise Server NX5822–BAS Dual-Domain Configurations • Table 2–8 lists component styles for these models. • Figure 2–7 and Figure 2–8 show the hardware configurations for system cabinets containing VX1305 and VX1505 based servers, respectively.
  • Page 52: Clearpath Enterprise Server Nx5822-Bas Dual-Domain Configurations

    NX5820 K Product Configurations Table 2–8. ClearPath Enterprise Server NX5822–BAS Dual-Domain Configurations Package Style NX5822–BAS Component Style Description Number of Processors or Common Components PROCESSORS NX5822-2D2 DUAL DOMAIN NX5822-2D3 DUAL DOMAIN NX5822-2D4 DUAL DOMAIN NX5822-2D5 DUAL DOMAIN NX5822-2D6 DUAL DOMAIN...
  • Page 53 NX5820 K Product Configurations Table 2–8. ClearPath Enterprise Server NX5822–BAS Dual-Domain Configurations Package Style NX5822–BAS Component Style Description Number of Processors or Common Components NX5820-DOC OPERATIONAL DOCUMENTS NX5820-MNT MAINTENANCE KIT NX5820-OPC OPERATIONAL CODE NX5820-PSB BASIC POWER SUPPLY COMPLEMENT NX5821-CCK DOM0 CARD COMPL, CIOM (1 CIOM, 1 KIUB)
  • Page 54: Servers

    Server Position 6 Server Position 1 Central Equipment Server Expansion Server Expansion Section Section Section 0706 Figure 2–7. NX5820 K Dual-Domain Redundant System Cabinet Configuration, with VX1305 Servers APC2 APC2 APC2 APC2 OSS7000 Peripheral Rack Server Position 7 Server Position 10...
  • Page 55: Nx5820 K Processor Package Style

    NX5820 K Processor Package Style Table 2–9 summarizes the processor with various performance levels package styles required for the various NX5820 K models. As noted in the component style charts, these package styles must be ordered separately from the system package style.
  • Page 56 NX5820 K Product Configurations Table 2–9. NX5820 K Processor Package Styles Package Package Component Description Style Style Style NX5821–1Dx NX5822–2Dx Model Models 2 3 4 5 6 7 8 A Dual-Domain, Dual-Processor Configuration PM3-CPU PROCESSOR MODULE CARD MSA104-193 MSUA BOARD, 4 REQUESTOR, W/192-MB...
  • Page 57: Cables

    Figure 2–9. Power Layout Redundant Power/Cooling Redundant power option is available for the NX5820 and NX5820 K product. Order one component style NX5800-RPW per domain. This style includes only redundant power and contains one ac/dc bulk power supply, one +5 volts dc/dc power supply, and one +3.3 volts dc/dc power supply.
  • Page 58: Nx5820 System Upgrades

    NX5820 System Upgrades NX5820 System Upgrades Table 2–10 lists the NX5820 System upgrades options. Figure 2–10 shows the upgrade paths for the NX5820 product models listed in Table 2–10. Table 2–11 through Table 2–13 list the components included within the upgrade package styles. Table 2–10.
  • Page 59: Nx5820 Upgrade Diagram

    NX5820 System Upgrades Single Domain Dual Domain Single Processor Multi Processor NX5821-31 NX582131-232 NX5822-32 System Package Style NX582131-141 NX582232-242 NXM582272-273 Upgrade Package Style NX5822-73 NX582141-242 NX5821-41 NX5822-42 NX582273-274 NX582242-252 NX582141-151 NX5822-74 NX582151-252 NX5822-52 NX5821-51 NX582274-275 NX582252-262 NX582151-161 NX5822-75 NX582161-262 NX5822-62 NX5821-61 NX562262-272 NX582275-276...
  • Page 60: Nx5820 Single Domain, Single Processor Model Upgrades (Sdsp To Sdsp)

    NX5820 System Upgrades Table 2–11. NX5820 Single Domain, Single Processor Model Upgrades (SDSP to SDSP) Package Converts Component Component Style Style Style Description From NX582131-141 NX5821-31 NX5821-41 NX582141-UDE FUNCTIONAL S/W, IP EMULATION NX5821-41 NX58412-PRM PROM, NX5820-41/42 NX582141-151 NX5821-41 NX5821-51 NX582151-UDE FUNCTIONAL S/W, IP EMULATION NX5821-51 NX58512-PRM PROM, NX5820-51/52...
  • Page 61: Nx5820 K System Upgrades

    NX5820 K System Upgrades Figure 2–11 shows the upgrade paths for the NX5820 K product models listed in Table 2–14. Table 2–14 lists all the NX5820 K System upgrade options. Table 2–15 through Table 2–19 list the components included within the upgrade package styles.
  • Page 62: Nx5820 K Upgrade Diagram

    NXU58223-PL4 NXU58213-PL4 Upgrade Package Style Proms and Microcode NX5822-PL4 NXU58225-2D6 NX5821-PL4 NXU58224-PL5 NXU58214-PL5 NX5822-2D6 NX5822-PL5 NX5821-PL5 NXU58226-2D7 NXU58225-PL6 NXU58215-PL6 NX5822-PL6 NX5822-2D7 NX5821-PL6 NXU58216-PL7 NXU58226-PL7 NXU58227-2D8 NX5822-PL7 NX5821-PL7 NX5822-2D8 NXU58228-2DA NX5822-2DA 0823 Figure 2–11. NX5820 K Upgrade Diagram 2–30 7017 6300–005...
  • Page 63: Nx5820 K Upgrade Options Summary

    NX5820 K System Upgrades Table 2–14. NX5820 K Upgrade Options Summary Upgrade Type Converts Package Style From Performance Upgrades for Single-Domain, NX5821-PL3 NX5821-PL4 NXU58213-PL4 Single- Processor Model Systems NX5821-PL4 NX5821-PL5 NXU58214-PL5 NX5821-PL5 NX5821-PL6 NXU58215-PL6 NX5821-PL6 NX5821-PL7 NXU58216-PL7 Single-Domain, Single-Processor to Dual-...
  • Page 64: Nx5820 K Single-Domain, Single-Processor To Dual Domain, Dual

    NX5820 K System Upgrades Table 2–16. NX5820 K Single-Domain, Single-Processor to Dual Domain, Dual- Processor Upgrade (SDSP to DDDP) Component Style Description Qty. Package Style NXD58211–2D2 Order one of the following performance level style to match existing domain: NX5821-PL3 with...
  • Page 65: Nx5820 K Performance Upgrades For Dual Domain, Dual-Processor Systems

    NX5820 K System Upgrades Table 2–17. NX5820 K Performance Upgrades for Dual Domain, Dual-Processor Systems Package Component Component Qty. Style Style Style Description NXU58223-PL4 NX5822-PL4 FUNCTIONAL SW/STYLE PROM PL4 LEVEL NXU58224-PL5 NX5822-PL5 FUNCTIONAL SW/STYLE PROM PL5 LEVEL NXU58225-PL6 NX5822-PL6 FUNCTIONAL SW/STYLE PROM PL6 LEVEL...
  • Page 66: Nx5820 K Dual Domain, Dual-Processor Multi-Processor Upgrades (Ddmp)

    NX5820 K System Upgrades Table 2–19. NX5820 K Dual Domain, Dual-Processor Multi-Processor Upgrades (DDMP) Component Style Description Qty. Package Style NXU58223–2D4 PM3-CPU PROCESSOR MODULE CARD COMPLEMENT NX5824-PL7 FUNCTIONAL SW/STYLE PROM, 74 LEVEL NX58274-PRK PROM LEVEL 74K Package Style NXU58224–2D5 PM3-CPU...
  • Page 67: Configuring System Options

    Configuring from NX5820 to NX5820 K systems NX5820 and NX5820 K Memory The NX5820 and NX5820 K utilizes the MSA and two styles of MSK memory boards for various system configurations. Each style of memory is unique to a range of system styles as follows: •...
  • Page 68: Through 72

    Each basic memory style board can be upgraded on a quadrant basis through the addition of DIMM sets. Refer to Table 3-2 for a description and comparison of the memory styles and upgrade components. Table 3–2. NX5820 and NX5820 K Memory Styles and Upgrade Components Style Description...
  • Page 69 NX5820 and NX5820 K Memory Table 3–2. NX5820 and NX5820 K Memory Styles and Upgrade Components (cont.) Style Description MSK208 Style Memory MSK208-384 Provides a basic eight requestor MSK memory board with two chip sets (four DRAMs) for a memory capacity of 384 megabytes of storage. Up to three boards, each orderable under style MEM298384-ADD, can be configured per domain.
  • Page 70: Msa104 Style Memory

    MSA104 Style Memory MSA104 Style Memory The minimum memory capacity per domain utilizing the MSA style memory board is 192 megabytes. Memory capacity may be expanded to 1152 megabytes per domain in increments of 192 megabytes by adding up to two additional MSA104-192 boards and an additional MOD192−DM2 per memory board.
  • Page 71: Msk208 Style Memory

    MSK208 Style Memory MSK208 Style Memory The minimum memory capacity per domain utilizing the MSK208 memory board is 384 megabytes. Memory capacity may be expanded to 2304 megabytes per domain in increments of 384 megabytes by adding up to two additional MSK208 memory boards and by adding two chip sets (four DIMMs) per memory board.
  • Page 72: Msk208 Board Layout

    MSK208 Style Memory Binary Value LVT16240 Bank/Segment Buffers ASIC number RAMPUP Circuit DRAM DRAM DRAM DRAM DRAM DRAM LVT16240 Buffers Binary Value Bank/Segment RAMPUP Circuit ASIC number JTAG MSUX ASIC Number MSK208 Memory Increments Storage Bank 0 Bank 0 Bank 1 Bank 1 Mwords MBytes...
  • Page 73: Msk412 Style Memory

    MSK412 Style Memory MSK412 Style Memory The minimum memory capacity per domain utilizing the MSK412 memory board is 384 megabytes. Memory capacity may be expanded to 4608 megabytes per domain in increments of 384 megabytes by adding up to two additional MSK412 memory boards and by adding six chip sets (twelve DIMMs) per memory board.
  • Page 74: Msk412 Board Layout

    MSK412 Style Memory Binary Value LVT16240 Bank/Segment Buffers ASIC number RAMPUP Circuit DRAM DRAM DRAM DRAM DRAM DRAM LVT16240 Buffers Binary Value Bank/Segment RAMPUP Circuit ASIC number MSUX ASIC Number MSK412 Memoru Increments Memory Incr Storage Bank 0 Bank 1 Bank 0 Bank 1 Bank 0...
  • Page 75: Memory Slot Locations

    A maximum of three MSA, MSK208 or MSK412 memory cards per domain can be configured. The maximum system capacity is 9216 megabytes using MSK412 memory cards. The memory card slot locations are listed in Table 3–3. Table 3–3. Memory Card Slot Locations NX5820 and NX5820 K DOMAIN 0 DOMAIN 1 MSA Style Memory...
  • Page 76: Iom Channel Expansion

    This style provides redundant SCP capability only on dual domain systems. Table 3–4. Redundant System Console Package Styles For NX5820 and Component Style Description NX5820 K Package Style RNX5820-SCP Quantity ADP68501-FTF 68F/50F SCSI ADAPTER CBL12-APX CABLE ASSY, 12 FEET APEX SWITCH...
  • Page 77: Configuring Redundant Switching Hubs

    The following considerations apply when configuring additional displays: • One monitor with keyboard and mouse is provided with the primary SCP (style NX5820-SCP for NX5820 and NX5820 K systems). This monitor is shared with the servers. • A second monitor with keyboard and mouse is provided with the redundant SCP option (style RNX5820-SCP for NX5820 and NX5820 K systems).
  • Page 78: Configuring Operator Display Workstations

    Is capable of running Windows NT workstation at 3.51 or higher operating system software − Has a copy of SCO XVision (PC1-XV) − Has Unisys custom SCP fonts (installed as part of the NX Administration utilities after installing SCO XVision) • Contains: −...
  • Page 79: Typical Client Supplied Single Odw Arrangement

    Configuring Additional Displays Table 3–5. Guidelines for Configuring SCP Monitors and ODW Displays Configuration Guideline Single-Domain/Non- One monitor with keyboard and mouse is supplied with the system. It is shared Redundant Dual Domain with all other servers (up to 7 servers total) via the eight-way ST selector. Up to six ODWs can be connected via the maintenance hub (Private LAN) and the switching hub (Public LAN).
  • Page 80: Work Space

    Table 3–6 lists the package styles that are used when converting single and dual domain NX5820 systems to NX5820 K systems. It also lists the component styles and quantity used in each package style. See ClearPath Enterprise Server NX5800 Upgrades/NX5820 Migration Installation Guide, 7016 7143 for conversion instructions.
  • Page 81: Conversion Package Styles For Nx5820 To Nx5820 K Systems

    Converting From NX5820 to NX5820 K Systems Table 3–6. Conversion Package Styles for NX5820 to NX5820 K Systems Conversion Converts Consists of Component Style Qty. Package Style From Single Domain Systems NXM582131-31K NX5821-31 NX5821-1D1/PL3 Migration KIU5820-PCA (KIUB BOARD) NXM5821-PL3 (Functional SW)
  • Page 82 Converting From NX5820 to NX5820 K Systems Table 3–6. Conversion Package Styles for NX5820 to NX5820 K Systems Conversion Converts Consists of Component Style Qty. Package Style From NXM582272-72K NX5822-72 NX5822-2D2/PL7 Migration KIU5820-PCA (KIUB BOARD) NXM5822-PL7 (Functional SW) NXM582272-PRK (PROM)
  • Page 83: Configuring I/O Cabinets And Channel Racks

    Section 4 Configuring I/O Cabinets and Channel Racks How to Use This Section This section provides guidelines for configuring universal cabinet (UC) style rack-mount (RM) cabinets: • • • • "Configuring I/O Cabinets" describes cabinet components and provides guidelines for configuring the cabinets.
  • Page 84: Cabinet Styles

    Configuring I/O Cabinets Table 4–1. Cabinet Styles Status Style Description Orderable BRM36-O First or only open-front style cabinet in a row. 36U high. BRM36-O2 Second and additional open-front style cabinets in a row. 36U high. Migration RM36-1 First or only louvered-door style cabinet in a row. 36U high. RM36-2 Second and additional louvered-door style cabinets in a row.
  • Page 85: Configuring Channel Racks

    Configuring Channel Racks Configuring Channel Racks Channel racks expand IOM connectivity beyond the channel slots provided in the system cabinet. Two styles of channel rack are available: • RM5-CA4 - With fascia for open-door style cabinets • RM5-CA5 - Without fascia, for louvered-door style cabinets Each channel rack connection requires: •...
  • Page 86: Channel Rack Components

    Configuring Channel Racks Table 4–3. Channel Rack Components Style Description • These are modular channel racks used with RM-style open-front I/O cabinets to RM5-CA4 and house external channel cards. RM5-CA5 • RM5-CA4 is with fascia, for BRM36-0 and BRM36-02 cabinets. •...
  • Page 87: Guidelines For Configuring Channel Racks

    Configuring Channel Racks Table 4–4. Guidelines for Configuring Channel Racks Area Rule/Recommendation 3U configurations Consists of four bays with four 3U channel slots each: 3U Bay 3U Bay (3rd) (4th) 3U Bay 3U Bay (1st) (2nd) Vertically adjacent bays can be electrically and logically configured so that one CS- bus can service two bays with up to eight channels.
  • Page 88: Configuring Power Net In Channel Racks

    Configuring Channel Racks Table 4–5. Configuring Power Net in Channel Racks Area Recommendation Configuration For NX5820 systems, if the channel racks are daisy chained to one another and the CEC section, use 9 Pin D to 9 Pin D Power Net cables (Style CBL8820-xxx, cable assembly 3446 6110-xxx).
  • Page 89: Configuring The Input/Output Module

    It covers that portion of the Input/Output system considered part of the central system; that is, from the IOB for the NX5820 or the KIUB for the NX5820 K to the Common Input/Output Module (CIOM) and including the channel interface.
  • Page 90: How The Iom Is Organized

    Each domain contains an IOM system. IOM Logical Organization Each IOM consists of two board types: • Input/Output Bridge (IOB) for NX5820 or KIUB for NX5820 K which provides connectivity between the system memory and the I/O bus. • Common Input/Output Module −...
  • Page 91: Iom Physical Organization

    Figure 5–2. NX5820 K IOM Organization IOM Physical Organization Each NX5820 and NX5820 K domain contains a front and rear card module assembly with specific locations for the IOB or KIUB, CIOMs, and internal channel rack. See Figure 5–3 for card module assembly for the NX5820 and Figure 5–4 for NX5820 K.
  • Page 92: Card Module Assembly For Nx5820

    How the IOM Is Organized First CIOM Per Domain CMF# Used for channels Channel Loads CMF0 External CMF0 and CMF4 are combined for 16 loads CMF4 Internal CMF1 External CMF1 and CMF5 are combined for 16 loads CMF5 Internal CMF2 External 16 loads CMF3...
  • Page 93: Iom Options

    Rear View The first CIOM board in the domain goes into this slot. Optionally dedicated for TCU functionality Optionally dedicated for Multi-IOU functionality 0700A Figure 5–4. Card Module Assembly for NX5820 K IOM Options • CMF external connectivity options •...
  • Page 94: Ciom Upgrade

    NX5820, up to a maximum of six (three per domain) additional CIOMs are allowed per system. For NX5820 K, up to a maximum of ten (five per domain) additional CIOMs are allowed per system. For additional CIOMs, order package style CIM9-ADD. It includes the following: −...
  • Page 95: Configuring Channels

    Configuring Channels Configuring Channels This subsection: • Identifies channel adapter styles supported on the system • Provides channel loading for supported styles • Provides guidelines for configuring channels • Provides typical channel configuration diagrams Styles Offered Table 5–2 identifies the channel adapter styles supported on the system. Channel adapters listed as "new"...
  • Page 96: Assigning Channel Loads

    Configuring Channels Assigning Channel Loads Table 5–3 provides CS-bus loading guidelines for the various channel configurations. CS-bus loading is dependent on bus demand factor (BDF), which provides a gauge of CS- bus availability when the channel requires service. When there are many channels on the CS-bus vying for service simultaneously, there is a low probability of any one of the channels being granted instantaneous access to the bus.
  • Page 97: Configuration Guidelines

    (All External) Note: For NX5820 Max Channels: 4 X CIOM/Domain (8 CIOMs) 254 Logical Channels per system Note: For NX5820 K Max Channels: 5 X CIOM/Domain (10 CIOMs) 254 Logical Channels per system 0712A Figure 5–5. CIOM/CMF/CS-BUS and Channel Diagram 7017 6300–005...
  • Page 98: Guidelines For Configuring Channels

    CS-bus connectivity, there are a maximum of 16 CS buses per domain for NX5820. When using up to 5 CIOMs with CS-bus connectivity, there are a maximum of 20 CS buses per domain for NX5820 K. For all models, one additional CS-bus interface is required for each server attached to the system.
  • Page 99 Up to two (one per domain) CIOM are required for IOU functionality. Total Channels for NX5820 K System: A total of 254 logical channels are available per system. For Domain 0, 162 physical channel connections are available (19 external CMFs x 8 = 152 channels plus 10 internal channels.
  • Page 100: Configuration Diagrams

    Configuring Channels Configuration Diagrams Figure 5–6 and Figure 5–7 are examples of typical channel configurations. Actual configurations may vary depending on the number and types of channels configured. Figure 5–8 shows the typical locations of the PCI thru card when used optionally to connect a server via the internal channel rack or remote channel rack.
  • Page 101: Single Domain Typical Channel Configuration

    Configuring Channels CIOM #0 Card Optional CIOM #1 Note: For NX5820 systems, this CIOM is Domain 0 Card for IOU functionality only. For NX5820 K, use for Multi-IOU functionality only. CS-4 CS-4 CS-4 CS-4 CMF0 CMF0 CMF0 CS-0 CMF1 CMF1...
  • Page 102: Dual Domain Typical Channel Configuration

    CS-2 PCI Bridge PCI Bridge (Via CSB3-15C cable) (Via CSB3-10C cable) For NX5820, IOU functionality only. For NX5820 K, Multi-IOU functionality CS-3 CS-3 only in Domain 0 or TCU functionality only in Domain 1. 0714A Figure 5–7. Dual Domain Typical Channel Configuration (One Internal CS Buss, Two Servers, and One External 8-Channel Buss per Domain) 5–14...
  • Page 103: Pcithru Feature Card

    CS-5 CMF3 CMF3 CMF3 CMF3 For NX5820, IOU functionality only. For NX5820 K, Multi-IOU functionality CS-3 CS-3 only in Domain 0 or TCU functionality only in Domain 1. 0714B Figure 5–8. Dual Domain Typical PCITHRU Card Location in the Internal and External Channel Racks 7017 6300–005...
  • Page 104: Pcithru Slot Versus Pci Bridge Jumper Positions

    PCITHRU Feature Card 0795 Jumper position 1 PCITHRU Channel Slot No. PCI Bridge Jumper Position Default jumper position Figure 5–9. PCITHRU Slot Versus PCI Bridge Jumper Positions 5–16 7017 6300–005...
  • Page 105: Configuring Qic Tape And Cd-Rom

    Configuring QIC Tape and CD-ROM Standard system models include both quarter-inch cartridge (QIC) tape and CD-ROM. Refer to the Unisys e-@ction ClearPath Enterprise Servers A Series and NX Systems I/O Configuration Guide (7008 6087) for guidelines on configuring these devices.
  • Page 106 Information Contained in the NX Systems I/O Configuration Guide • Peripheral devices supported on the system: − Comprehensive listing of device styles − Migration/new qualification status − Channel types − PCD control names − PCD/MCP names • Peripheral configuration and power control addressing: −...
  • Page 107: Configuring The Servers

    Section 6 Configuring the Servers How This Section Is Organized This section contains the following information: • Describes the features provided with − VX1305-BSE/-BSU servers − VX1505-BSE/ -BSU servers − ES2024R servers (Package Style ESR202141-GZN) − ES5044R servers (Package Style ESR504141-GZN) −...
  • Page 108: Vx1305 Servers

    VX1305 Servers Note: This configuration guide lists the basic features and options offered with VX1305 servers. The VX1305 server supports Windows NT. Your Unisys representative can provide details on server options available beyond those documented here. VX1305 Basic Features •...
  • Page 109: Basic Features, Vx1305 Servers

    VX1305 Servers Table 6–1. Basic Features, VX1305 Servers VX1305 Processors Memory 10/100 3.5-Inch CD-ROM RAID Servers Mbps LAN 1.44-MB Drive Tape 9-GB Interface Floppy Drive Hard Disk Drives Disk Drive Min. Max. Std. Std. Std. Std. Std. Max. 1,6,7 Per Server 1 to 2 256-MB 1-GB...
  • Page 110: Road Map For Ordering Vx1305 Servers

    VX1305 Servers Server B Server A (Optional) (Required) QTY. 1 QTY. 1 Server Server VX1305-BSU VX1305-BSE QTY. 0 - 1 QTY. 0 - 1 DSR2450-512 DSR2450-512 or DSR3500-512 or DSR3500-512 Additional Additional (Currently available) (Currently available) Processors Processors DSR200081-P2U DSR200081-P2U Additional QTY.
  • Page 111: Server Components

    VX1305 Servers Server Components This subsection provides ordering information for VX1305-BSE/-BSU server components Orders for server A (server position 1) must include the following: • VX1305-BSE (Table 6-2) • Additional processor, if any (Table 6–3) • Additional memory, if any (Table 6–4) •...
  • Page 112: Add-On Processor Board

    VX1305 Servers Table 6–2. VX1305-BSE/-BSU Basic Components Component Description Style Name ADP68501-FTF 68F/50F SCSI CABLE ADAPTER CAG31-DR2 3X RAID CAGE, DR2 CBL321-SFR INT SCSI SFR OPTION CDR1432-SI 14X-32X SCSI CD-ROM DIM10072-256 PC 100 MHz SDRAM 256MB DR20001-OK1 OPERATING KIT DR200081-LBN DR/2 FOR NT DR200081-Z DR/2 RACKMOUNT SERVER- CHASSIS...
  • Page 113: Additional Memory Packages

    VX1305 Servers Additional Memory Packages Table 6–4 lists the additional memory packages available for use with VX1305 servers at time of initial system order. Table 6–4. Memory Packages, VX1305 Servers Style Number Qty. Description Additional Memory DIM10072-256 PC 100 MHz SDRAM, 256MB Notes: 1.
  • Page 114: Optional User Access Components

    VX1305 Servers Optional User Access Components Table 6–6 lists components included with the optional user access components package, style VX4000-CP3. Table 6–6. VX4000-CP3 Optional User Access Components, VX1305 Servers Style Number Qty. Description B25-LC Line Cord (Note 1) EVG2100-P 15-Inch Monitor, Color PCK1-EXT Cable M to F PS2 Keyboard EXT PCK104-SKB...
  • Page 115: Configuration Guidelines Vx1305

    VX1305 Servers Configuration Guidelines VX1305 Table 6–7 lists guidelines for configuring VX1305 servers. Figure 6–2 shows the connection from a VX1305 server to the CIOM card in the CEC module or to the PCI Thru card in channel racks. Table 6–7. Configuration Guidelines, VX1305 Servers Area Rule/Recommendation See Table 6–5 for details.
  • Page 116: Vx1505 Servers

    VX1505 Servers VX1505 Servers Note: This configuration guide lists the basic features and options offered with VX1505 servers. The VX1505 servers supports Windows NT. Your Unisys representative can provide details on server options available beyond those documented here. VX1505 Basic Features •...
  • Page 117: Basic Features, Vx1505 Servers

    VX1505 Servers Table 6–8. Basic Features, VX1505 Servers VX1505 Processors Memory 10/100 3.5-Inch CD-ROM RAID 2,3,8 Servers Mbps LAN 1.44-MB Drive Tape 9-GB Interface Floppy Drive Hard Disk Drives Disk Drive Min. Max. Std. Std. Std. Std. Std. Max. 1,6,7 Per Server 1 to 4 0.5-MB...
  • Page 118: Server Components

    VX1505 Servers Table 6–9. VX1505-BSE Processor Requirements No. of Installed VRMs Terminators Notes Processors Required Required 1st processor requires 2 VRMs. 3 terminators are required (XER2400-TRM) 2nd processor requires 1 additional VRM. 2 terminators are required (XER2400-TRM) 3rd processor requires 2 additional VRMs. 1 terminator is required (XER2400-TRM) 4th processor requires 1 additional VRM.
  • Page 119: Road Map For Ordering Vx1505 Servers

    VX1505 Servers Server A Server B (Required) (Optional) QTY. 1 QTY. 1 Server Server B VX1505-BSU VX1505-BSE Qty. 1 - 4 Qty. 1 - 4 XER2450-512 450 MHZ, 512K Cache XER2450-512 450 MHZ, 512K Cache XER2450-1MB 450 MHZ, 1MB Cache XER2450-1MB 450 MHZ, 1MB Cache XER2450-2MB...
  • Page 120: Basic Server Components And Optional Redundant Power Supply

    OPERATING KIT ESR204151-Z Z-BOX QUAD 10 SLOT ESS2000-ANL FILE MGT: EX ANALYSIS.MRC ESS2000-INS FILE MGT: ES INTALL MGR ESS99-AGT FILE MGT: UNISYS AGENTS ESS99-FWK FILE MGT: CA FRAMEWORK ETH1010052-PCI INTEL 10/100 NETWORK ADAPTER HDL917-CX1 9-GB SCSI HDD SCA RAD302-BAT BATTERY BACKUP MODULE...
  • Page 121: Processors

    VX1505 Servers Processors Table 6–11 lists the processor boards available for use with VX1505 servers. Table 6–11. Processors, VX1505 Servers Component Description Qty. Style Number Processors XER2450-512 Pentium II Xeon CPU, 450-Mhz, 512KB cache 1 to 4 XER2450-1MB Pentium II Xeon CPU, 450-Mhz, 1MB cache 1 to 4 XER2450-2MB Pentium II Xeon CPU, 450-Mhz, 2MB cache...
  • Page 122: Connection Packages And Optional Pci Thru Card

    VX1505 Servers Connection Packages and Optional PCI Thru Card Table 6–13 list components included with the connection packages for VX1505 servers. Table 6–13. Connection Package Components, VX1505 Servers Component Style Description Package Style Name (Included with NX5820-1NT NXU5810-NT Package Style) CBL25-APX 25-FOOT CABLE ASSEMBLY CSB3-15C...
  • Page 123: Optional User Access Components

    VX1505 Servers Optional User Access Components Table 6–14 lists components included with the optional user access components package, style VX4000-CP3. Table 6–14. VX4000-CP3 Optional User Access Components, VX1505 Servers Style Number Qty. Description B25-LC Line Cord (Note 1) EVG2100-P 15-Inch Monitor, Color PCK1-EXT Cable M to F PS2 Keyboard EXT PCK104-SKB...
  • Page 124: Configuration Guidelines Vx1505

    VX1505 Servers Configuration Guidelines VX1505 Table 6–15 lists guidelines for configuring VX1505 servers. Figure 6–4 shows the connection from a VX1505 server to the CIOM card in the CEC module or to the PCI Thru card in channel racks. Table 6–15. Configuration Guidelines, VX1505 Servers Area Rule/Recommendation See Table 6–13 for details.
  • Page 125: Es5085R Servers

    ES5085R Servers ES5085R Servers Basic Features • One to ten (Five maximum per domain) − ES5085R servers (Package Style ESR508151-GZN) • One to eight 550-Mhz processors per server (all processor within a server must be the same style) • One or two memory card per server −...
  • Page 126: Basic Features, Es5085R Servers

    ES5085R Servers Table 6–16. Basic Features, ES5085R Servers ES5085R Processors Memory 3.5-Inch CD-ROM RAID Servers 1.44-MB Drive Tape Drive Hard Disk Floppy Drives Disk Drive Min. Max. Std. Std. Std. Std. Max. 1,5,6,8 Per Server 1 to 8 0.5-MB 16-GB Notes: 1.
  • Page 127: Server Components

    ES5085R Servers Server Components This subsection provides ordering information for ES5085R server components Orders for initial server A (server position 1) must include the following: • Package style ESR508151-GZN • Processors, if any (Table 6–17) • Memory packages (Table 6–18) •...
  • Page 128: Road Map For Ordering Es5085R Servers

    ES5085R Servers Initial Additional Server Server QTY. 1 QTY. 1 ES5085R Package Style ES5085R Package Style (ESR508151-GZN) (ESR508151-GZN) Qty. 1 - 8 Qty. 1 - 8 XEO3550-512 550 MHZ, 512K Cache XEO3550-512 550 MHZ, 512K Cache XEO3550-1MB 550 MHZ, 1MB Cache XEO3550-1MB 550 MHZ, 1MB Cache Processors...
  • Page 129: Processors

    ES5085R Servers Processors Table 6–17 lists the processor boards available for use with ES5085R servers. Table 6–17. Processors, ES5085R Servers Component Description Qty. Style Number Processors XEO3550-512 Pentium III Xeon CPU, 550-Mhz, 512KB cache 1 to 8 XEO3550-1MB Pentium III Xeon CPU, 550-Mhz, 1MB cache 1 to 8 XEO3550-2MB Pentium III Xeon CPU, 550-Mhz, 2MB cache...
  • Page 130: Connection Packages And Optional Pci

    ES5085R Servers Connection Packages and Optional PCI Table 6–19 list components included with the connection packages for ES5085R servers. Table 6–19. Connection Package Components, ES5085R Servers Component Style Description Package Style Name (Included with NX508151-1NT NXU508151-NT Package Style) CBL25-APX 25-FOOT CABLE ASSEMBLY CSB3-15C CSB3 15 FOOT CABLE ASSEMBLY, COAX CSB3-PCI...
  • Page 131: Optional User Access Components

    ES5085R Servers Optional User Access Components Table 6–20 lists components included with the optional user access components package, style VX4000-CP3. Table 6–20. VX4000-CP3 Optional User Access Components, ES5085R Servers Style Number Qty. Description B25-LC Line Cord (Note 1) EVG2100-P 15-Inch Monitor, Color PCK1-EXT Cable M to F PS2 Keyboard EXT PCK104-SKB...
  • Page 132: Es2024R Servers

    ES2024R Servers ES2024R Servers Basic Features • One to ten (Five maximum per domain) − ES2024R servers (Package Style ESR202141-GZN) • One or two processors per server (all processor within a server must be the same style) • One or two memory card per server −...
  • Page 133: Basic Features, Es2024R Servers

    ES2024R Servers Table 6–21. Basic Features, ES2024R Servers ES2024R Processors Memory 3.5-Inch CD-ROM RAID Servers 1.44-MB Drive Tape Drive Hard Disk Floppy Drives Disk Drive Min. Max. Std. Std. Std. Std. Max. 1,4,6 Per Server 1 to 2 0.5-MB 16-GB Notes: 1.
  • Page 134: Server Components

    ES2024R Servers Server Components This subsection provides ordering information for ES2024R server components Orders for initial server A (server position 1) must include the following: • Package style ESR502141-GZN • Processors, if any (Table 6–22) • Memory packages (Table 6–23) •...
  • Page 135: Road Map For Ordering Es2024R Servers

    ES2024R Servers Initial Additional Server Server QTY. 1 QTY. 1 ES2024R Package Style ES2024R Package Style (ESR202141-GZN) (ESR202141-GZN) Qty. 1 - 2 Qty. 1 - 2 CPU3667133-256 667 MHZ, 256OD/133FSB CPU3667133-256 667 MHZ, 256OD/133FSB CPU3733133-256 733 MHZ, 256OD/133FSB CPU3733133-256 733 MHZ, 256OD/133FSB CPU3800133-256 CPU3800133-256 Processors...
  • Page 136: Processors

    ES2024R Servers Processors Table 6–22 lists the processor boards available for use with ES2024R servers. Table 6–22. Processors, ES2024R Servers Component Style Description Qty. Number Processors CPU3667133-256 Pentium III CPU, 667-Mhz, 256 OD/133 FSB 1 to 2 CPU3733133-256 Pentium III CPU, 733-Mhz, 256 OD/133 FSB 1 to 2 CPU3800133-256 Pentium III CPU, 800-Mhz, 256 OD/133 FSB...
  • Page 137: Connection Packages And Optional Pci

    ES2024R Servers Connection Packages and Optional PCI Table 6–24 list components included with the connection packages for ES2024R servers. Table 6–24. Connection Package Components, ES2024R Servers Component Style Description Package Style Name (Included with NX502141-1NT NXU502141-NT Package Style) CBL25-APX 25-FOOT CABLE ASSEMBLY CSB3-15C CSB3 15 FOOT CABLE ASSEMBLY, COAX CSB3-PCI...
  • Page 138: Optional User Access Components

    ES2024R Servers Optional User Access Components Table 6–25 lists components included with the optional user access components package, style VX4000-CP3. Table 6–25. VX4000-CP3 Optional User Access Components, ES2024R Servers Style Number Qty. Description B25-LC Line Cord (Note 1) EVG2100-P 15-Inch Monitor, Color PCK1-EXT Cable M to F PS2 Keyboard EXT PCK104-SKB...
  • Page 139: Es5044R Servers

    ES5044R Servers ES5044R Servers Basic Features • One to ten (Five maximum per domain) − ES5044R servers (Package Style ESR504141-GZN) • One or four processors per server (all processor within a server must be the same style) • One or two memory card per server −...
  • Page 140: Basic Features, Es5044R Servers

    ES5044R Servers Table 6–26. Basic Features, ES5044R Servers ES5044R Processors Memory 3.5-Inch CD-ROM RAID Servers 1.44-MB Drive Tape Drive Hard Disk Floppy Drives Disk Drive Min. Max. Std. Std. Std. Std. Max. 1,5,6,8 Per Server 1 to 4 256-MB 8-GB Notes: 1.
  • Page 141: Server Components

    ES5044R Servers Server Components This subsection provides ordering information for ES5044R server components Orders for initial server A (server position 1) must include the following: • Package style ESR504141-GZN • Processors, if any (Table 6–27) • Memory packages (Table 6–28) •...
  • Page 142: Road Map For Ordering Es5044R Servers

    ES5044R Servers Initial Additional Server Server QTY. 1 QTY. 1 ES5044R Package Style ES5044R Package Style (ESR504141-GZN) (ESR504141-GZN) Qty. 1 - 4 Qty. 1 - 4 XEO37001-1MB 700 MHZ, 1MB Cache XEO37001-1MB 700 MHZ, 1MB Cache XEO37001-2MB XEO37001-2MB 700 MHZ, 2MB Cache 700 MHZ, 2MB Cache Processors Processors...
  • Page 143: Processors

    ES5044R Servers Processors Table 6–27 lists the processor boards available for use with ES5044R servers. Table 6–27. Processors, ES5044R Servers Component Style Description Qty. Number Processors XEO37001-1MB Pentium III Xeon 700 MHz, 1MB cache 1 to 4 XEO37001-2MB Pentium III Xeon 700 MHz, 2MB, cache 1 to 4 XEO38001-2MB Pentium III Xeon 800 MHz, 2MB, cache...
  • Page 144: Connection Packages And Optional Pci

    ES5044R Servers Connection Packages and Optional PCI Table 6–29 list components included with the connection packages for ES5044R servers. Table 6–29. Connection Package Components, ES5044R Servers Component Style Description Package Style Name (Included with NX504141-1NT NXU504141-NT Package Style) CBL23341-F3 ACC:INT U/WIDE 40IN SCSI CBL25-APX 25-FOOT CABLE ASSEMBLY CSB3-15C...
  • Page 145: Optional User Access Components

    ES5044R Servers Optional User Access Components Table 6–30 lists components included with the optional user access components package, style VX4000-CP3. Table 6–30. VX4000-CP3 Optional User Access Components, ES5044R Servers Style Number Qty. Description B25-LC Line Cord (Note 1) EVG2100-P 15-Inch Monitor, Color PCK1-EXT Cable M to F PS2 Keyboard EXT PCK104-SKB...
  • Page 146: Configuring The Private Maintenance Hub And Public Switching Lan

    Configuring the Private Maintenance Hub and Public Switching LAN Configuring the Private Maintenance Hub and Public Switching LAN Tables 6–31 and 6–32 show the assignment for a single domain system with one or two switching LANs, respectively. Table 6–31. Configuring Single Domain Maintenance Hub and One Switching LAN Private Maintenance Hub A (Net Gear EN516) Port Destination...
  • Page 147 Configuring the Private Maintenance Hub and Public Switching LAN Table 6–31. Configuring Single Domain Maintenance Hub and One Switching LAN Using Public Switching LAN A (Cisco 2924 XL) Port Destination Comments NT Server A NT Server C Optional NT Server E Optional NT Server G Optional...
  • Page 148: Configuring Single Domain Maintenance Hub And Two Switching Lans

    Configuring the Private Maintenance Hub and Public Switching LAN Table 6–32. Configuring Single Domain Maintenance Hub and Two Switching LANs Private Maintenance Hub A (Net Gear EN516) Port Destination Comments SCP Console A NT Server A NT Server C Optional NT Server E Optional NT Server G...
  • Page 149 Configuring the Private Maintenance Hub and Public Switching LAN Table 6–32. Configuring Single Domain Maintenance Hub and Two Switching LANs Using Public Switching LAN B (Bay Network 350 T) Port Destination Comments 802.3 Domain 0 – LAN 1 Public Switching LAN A – Port 14 Optional To customer’s public LAN Optional...
  • Page 150 Configuring the Private Maintenance Hub and Public Switching LAN Table 6–32. Configuring Single Domain Maintenance Hub and Two Switching LANs Using Public Switching LAN B (Cisco 2924 XL) Port Destination Comments 802.3 Domain 0 – LAN 1 Optional Optional Public Switching LAN A – Port 19 To customer’s public LAN Optional 6–44...
  • Page 151: Configuring Dual Domain Maintenance Hub And One Public Switching Lan

    Configuring the Private Maintenance Hub and Public Switching LAN Table 6–33 shows the assignment for a dual domain systems with one Public Switching LAN. Table 6–33. Configuring Dual Domain Maintenance Hub and One Public Switching LAN Private Maintenance Hub A (Net Gear EN516) Port Destination Comments...
  • Page 152 Configuring the Private Maintenance Hub and Public Switching LAN Table 6–33. Configuring Dual Domain Maintenance Hub and One Public Switching LAN (Cont.) Using Public Switching LAN A (Bay Network 350 T) Port Destination Comments NT Server A NT Server B Optional NT Server C Optional...
  • Page 153: Configuring Dual Domain Maintenance Hub And Two Public Switching

    Configuring the Private Maintenance Hub and Public Switching LAN Table 6–34 shows the assignment for a dual domain systems with two Public Switching LAN. Table 6–34. Configuring Dual Domain Maintenance Hub and Two Public Switching LANs Private Maintenance Hub A (Net Gear EN516) Port Destination Comments...
  • Page 154 Configuring the Private Maintenance Hub and Public Switching LAN Table 6–34. Configuring Dual Domain Maintenance Hub and Two Public Switching LANs Using Public Switching LAN A (Bay Network 350 T) Port Destination Comments NT Server I Optional 802.3 Domain 0 – LAN 0 802.3 Domain 1 –...
  • Page 155 Configuring the Private Maintenance Hub and Public Switching LAN Table 6–34. Configuring Dual Domain Maintenance Hub and Two Public Switching LANs Using Public Switch LAN A (Cisco 2924 XL) Port Destination Comments 802.3 Domain 0 – LAN 0 802.3 Domain 1 – LAN 1 Optional Optional Public Switching LAN B –...
  • Page 156: Configuring Optional And Recommended Ups

    Configuring Optional and Recommended UPS Configuring Optional and Recommended UPS The Uninterruptible Power Supply (UPS) option enables the system to gracefully shut down in the event of a power interruption on the main supply line The available styles are listed in Table 6–35. If the site UPS does not provide power and status to the entire system (CEC, APC, etc), it should provide power and status connections for the SCP’s and all servers.
  • Page 157 Configuring Optional and Recommended UPS Table 6–35. UPS Options Component Interconnect Configuration and Industry-Compatible UPS Systems Notes Style Name Cable Part No. UPS915-WC6 15-Pin Male “D” to 9-Pin Male Deltec 90S 1, 2, 7 (7015 5411-001) 9-Pin Male “D” to 9-Pin Male Deltec 6000 1, 2, 7 (7015 6260-003)
  • Page 158 Configuring Optional and Recommended UPS Table 6–36. Status Selection Between SCP’s and Servers VX1305-BSE/BSU Servers FROM\TO SCP A SCP B SERVER A SERVER B SERVER C SERVER D SCP A CBL5-UPS CBL5-UPS CBL10-UPS CBL15-UPS SCP B CBL5-UPS CBL5-UPS CBL15-UPS SERVER A CBL5-UPS CBL5-UPS CBL10-UPS...
  • Page 159: Single Scp/Server To Ups Status Cable Connections (Site Ups Installed)

    Configuring Optional and Recommended UPS Jumper cable for NT server (Part of style UPS111-EXP) 7015 7789-000 Last Server Interconnect Box 7016 0619-001 (Part of style UPS111-EXP) Jumper cable for NT server (Part of style UPS111-EXP) 7015 7789-000 First Server Interconnect Box 7016 0619-001 (Part of style UPS111-EXP) Interconnect Cable...
  • Page 160: Dual Scp/Server To Ups Status Cable Connections (Site Ups Installed)

    Configuring Optional and Recommended UPS Jumper cable 7015 7789-000 Ser 1 Ser 2 (Note 3) Last Server Interconnect Box SER 2 7016 0609 (COM 2) (Note 3) Jumper cable 7015 7789-000 (Note 3) Ser 1 Ser 2 First Server Interconnect Box SER 2 7016 0609 (Note 3)
  • Page 161: Scp To Ups Status Cable

    Configuring Optional and Recommended UPS If a site UPS is not used, Unisys highly recommends at a minimum that a small individual UPS’s provided power and status connections to each SCP in the system (2 UPS for redundant SCP). For this application, a small UPS can be obtained from Unisys Direct (Model PRC1000i) to supply power and status for each SCP.
  • Page 162 Configuring Optional and Recommended UPS 6–56 7017 6300–005...
  • Page 163: Connecting Other Host Systems

    Section 7 Connecting Other Host Systems Table 7–1 lists guidelines for connecting other host systems via the I/O subsystem. Table 7–1. Guidelines for Connecting Other Host Systems Area Rule/Recommendation Software level The system software must be at or higher than the level specified in the I/O Configuration Guide for the specific I/O subsystem being configured.
  • Page 164 Connecting Other Host Systems 7–2 7017 6300–005...
  • Page 165: Glossary

    Glossary Automatic Power Control ASIC Application specific integrated circuit Asynchronous transfer mode Common scan engine central processing module (CPM) The computer hardware unit that controls and executes the instructions contained in object code files. Also called processing module (PM) and instruction processor (IP). channel, channel adapter The hardware that interfaces the CMF with external I/O devices via a standard electrical protocol for data transfer, including SCSI, MLI, FDDI, 802.3, and ATM electrical protocols.
  • Page 166 Glossary Direct access channel DDMP Dual-domain, multiple-processor DIMM Dual inline memory module data transfer unit (DTU) The subunit of an I/O module (IOM) that provides memory-to-memory data transfers for use in disk caching. data transfer facility (DTF) enhanced DTU dual domain adapter (DDA) Required for dual-domain models.
  • Page 167 Glossary IOCB Input/Output Control Block I/O module (IOM) (1) A hardware module that interfaces with the I/O subsystem and schedules tasks by using a message protocol. (2) A group of units that control input/output on a system, including the task control unit (TCU), input/output unit (IOU), channel manager facility (CMF), and interface adapters (IAs).
  • Page 168 Glossary MSUA Memory storage unit A style MSUK Memory storage unit K style memory storage unit (MSU) One of up to three storage modules in each domain of the NX5820 that contains a 96-MB expansion module (MEM96-MOD) and can be expanded to 384 MB in 96-MB increments using MEM96-MOD and/or MEM96-DCM memory expansion modules.
  • Page 169 Glossary Uninterruptible power supply Unity storage device 7017 6300–005 Glossary–5...
  • Page 170 Glossary Glossary–6 7017 6300–005...
  • Page 171: Configuring Dual Domain Maintenance Hub And Two Public Switching Lans

    Index ClearPath Enterprise Server NX5821 Single- Domain, Single-Processor (SDSP) Configurations Models 31 through acronyms, system components, 1-7 71, 2-3 Additional Memory Packages, 6-7 ClearPath Enterprise Server NX5821-BAS Add-On Processor Board, 6-6 Single-Domain, Single-Processor Add-On Processor Board, VX1305 Servers, 6-6 (SDSP) Configurations, 2-15 array processing, 1-2 ClearPath Enterprise Server NX5822 Basic Dual-Domain Configurations, 2-19...
  • Page 172: Memory Card Slot Locations

    Expansion Box Options, 6-51 NX5620 Upgrade Diagram, 2-30 NX5820 Companion Package Style, 2-11 NX5820 Expansion Sections, 1-5 NX5820 K Processor Package Style, 2-23 NX5820 K Product Configurations, 2-15 NX5820 K Products, 2-12 Guidelines for Connecting Other Host NX5820 K System Upgrades, 2-29 Systems, 7-1 Index–2...
  • Page 173: Ups Options

    Index NX5820 Memory, 3-1 Standalone (PRC1000i) UPS to SCP NX5820 Product Configurations, 2-3 Cabling, 6-55 NX5820 Products, 2-1 Status Selection Between SCP’s and NX5820 System Upgrades, 2-26 Servers, 6-52 Styles Offered, 5-7 supported peripherals and DLPs, 1-6 SVGA monitor, 1-4, 1-5 system cooling, 1-2 operator display terminal (ODT), 3-11...
  • Page 174 Index VX1505 Servers, 6-10 VX1505 Single-Server to Multi-Server Upgrades, 6-17 VX1505-BSE Processor Requirements., 6-12 VX4000-CP3 Optional User Access Components, ES2024R Servers, 6-32 VX4000-CP3 Optional User Access Components, ES5044R Servers, 6-39 VX4000-CP3 Optional User Access Components, ES5085R Servers, 6-25 VX4000-CP3 Optional User Access Components, VX1305 Servers, 6-8 Index–4 7017 6300–005...
  • Page 176 *70176300-005* 7 0 1 7 6 3 0 0 –0 0 5...

This manual is also suitable for:

Nx5820

Table of Contents