Sign In
Upload
Manuals
Brands
Unisys Manuals
Server
NX5820
Unisys NX5820 Manuals
Manuals and User Guides for Unisys NX5820. We have
1
Unisys NX5820 manual available for free PDF download: Configuration Manual
Unisys NX5820 Configuration Manual (176 pages)
Brand:
Unisys
| Category:
Server
| Size: 1.12 MB
Table of Contents
Table of Contents
9
About this Guide
17
How to Use this Guide
18
What Product Models Are Covered
22
System Architecture
22
Features
22
Technology Enhancements
22
Clearpath Enterprise Server NX Product Models Covered in this Guide
22
System Partitioning
23
Dual Domain
23
Single Monolithic Partition
23
Two Separate Partitions
23
Single Domain
23
Hardware Overview
24
Type of Computing System
24
The System Cabinet
24
Central Equipment Complex (CEC) Section
24
Expansion Sections
25
SVGA Monitor and Keyboard with Mouse
25
The I/O Subsystem
25
Rack-Mounted Devices
25
Other I/O Devices
26
System Cabinet Organization
26
Acronyms for System Components
27
Typical View of Clearpath Enterprise Server NX5820 and NX5820 K with
28
System Cabinet PCA Locations for NX5820
29
Block Diagram of Clearpath Enterprise Server NX5820 and NX5820 K
30
System Cabinet PCA Locations for NX5820 K
30
Block Diagram of Clearpath Enterprise Server NX5820 and NX5820 K in
31
Supported Peripherals
26
System Components
26
System Components
31
Block Diagram of Clearpath Enterprise Server NX5820 and NX5820 K in Dual-Domain, Redundant-Console/Redundant Public Switch Configuration
32
Configuring System Hardware
33
How this Section Is Organized
33
NX5820 Products
33
Single-Domain, Single-Processor (SDSP) NX5821 Models 31 to 71
33
Clearpath Enterprise Server NX5820 Product Models
34
NX5820 Product Configurations
35
Clearpath Enterprise Server NX5821 Single-Domain, Single-Processor
35
Clearpath Enterprise Server NX5821 Single-Domain, Single-Processor (SDSP) Configurations Models 31 through 71
35
NX5820 Single-Domain System Cabinet Configuration with VX1305
37
Clearpath Enterprise Server NX5822 Dual-Domain, Multi-Processor (DDMP) Configurations Models
38
NX5820 Single-Domain Cabinet Configuration, with VX1505 Servers
38
Through 78
39
Clearpath Enterprise Server NX5822 Dual-Domain, Multi-Processor Models
39
Clearpath Enterprise Server NX5822 Dual-Domain, Multi-Processors
40
NX5820 Dual-Domain Redundant System Cabinet Configuration, with
42
NX5820 Dual-Domain System Cabinet Configuration, with VX1505
42
NX5820 Companion Package Style
43
NX5820 Companion Styles
43
NX5820 K Products
44
Dual-Domain, Dual Processor (DDDP) NX5822 - BAS Models
44
Single-Domain, Single-Processor (SDSP) NX5821 - BAS Models
44
Dual-Domain, Multiple-Processor (DDMP) NX5822 - BAS Models
45
Clearpath Enterprise Server NX5820 K Product Models
46
NX5820 K Product Configurations
47
Clearpath Enterprise Server NX5821-BAS Single-Domain, Single-Processor (SDSP) Configurations
47
Clearpath Enterprise Server NX5821-BAS Single-Domain, Single-Processor Configurations
48
NX5820 K Single-Domain System Cabinet Configuration with VX1305 Servers
50
Clearpath Enterprise Server NX5822-BAS Dual-Domain Configurations
51
NX5820 K Single-Domain Cabinet Configuration, with VX1505 Servers
51
Clearpath Enterprise Server NX5822-BAS Dual-Domain Configurations
52
Servers
54
NX5820 K Dual-Domain Redundant System Cabinet Configuration, with VX1305 Servers
54
NX5820 K Dual-Domain System Cabinet Configuration, with VX1505 Servers
54
NX5820 K Processor Package Style
55
NX5820 K Processor Package Styles
55
Cables
57
Power Layout
57
Power Layout and Requirements
57
Redundant Power/Cooling
57
NX5820 System Upgrade Options Summary
58
NX5820 Upgrade Diagram
59
NX5820 Single Domain Single Processor to Dual Domain Dual Processor Upgrades (SDSP to DDDP)
60
NX5820 System Upgrades
58
NX5820 K System Upgrades
61
NX5820 Single Domain, Single Processor Model Upgrades (SDSP to SDSP)
60
NX5820 Dual Domain Multi Processor Upgrades (DDMP to DDMP)
61
NX5820 K Upgrade Diagram
62
NX5820 K Upgrade Options Summary
63
Performance Upgrades for Single-Domain, Single-Processor Systems
63
NX5820 K Single-Domain, Single-Processor to Dual Domain, Dual
64
Processor Upgrade (SDSP to DDDP)
64
NX5820 K Dual Domain, Dual-Processor to Dual Domain, Multi-Processor Upgrade (DDDP to DDMP)
65
NX5820 K Performance Upgrades for Dual Domain, Dual-Processor Systems
65
NX5820 K Dual Domain, Dual-Processor Multi-Processor Upgrades (DDMP)
66
Configuring System Options
67
How this Section Is Organized
67
NX5820 and NX5820 K Memory
67
Through 72
68
Basic Memory Board Configuration by System Style
68
NX5820 and NX5820 K Memory Styles and Upgrade Components
68
MSA104 Style Memory
70
MSA Board Layout
70
MSK208 Style Memory
71
MSK208 Board Layout
72
MSK412 Style Memory
73
MSK412 Board Layout
74
Memory Slot Locations
75
IOM Channel Expansion
76
Redundant System Console Package Styles
76
Configuring Redundant SCP for the NX5820 and NX5820 K
76
Configuring Redundant Switching Hubs
77
Configuring Additional Displays
77
Configuring Operator Display Workstations
78
Configuration Guidelines for SCP Monitors and ODW Displays
78
Guidelines for Configuring SCP Monitors and ODW Displays
79
Work Space
80
Typical Client Supplied Single ODW Arrangement
79
Redundant Power for the NX5820 and NX5820 K
80
Conversion Package Styles for NX5820 to NX5820 K Systems
81
Configuring Additional OSS7000 Devices
80
Converting from NX5820 to NX5820 K Systems
80
Configuring I/O Cabinets and Channel Racks
83
How to Use this Section
83
Configuring I/O Cabinets
83
Cabinet Styles
84
Configuration Guidelines for I/O Cabinets
84
Configuring Channel Racks
85
Channel Rack Components
86
Guidelines for Configuring Channel Racks
87
Configuring Power Net in Channel Racks
88
Configuring the Input/Output Module
89
Introduction
89
How this Section Is Organized
89
How the IOM Is Organized
90
IOM Logical Organization
90
NX5820 IOM Organization
90
IOM Physical Organization
91
NX5820 K IOM Organization
91
Card Module Assembly for NX5820
92
IOM Options
93
CMF External Connectivity
93
Card Module Assembly for NX5820 K
93
CIOM Upgrade
94
CMF External Connectivity Options
94
Configuring Channels
95
Styles Offered
95
Supported Channel Adapter Types
95
Assigning Channel Loads
96
CIOM CS-Bus Channel Loading
96
Configuration Guidelines
97
CIOM/CMF/CS-BUS and Channel Diagram
97
Guidelines for Configuring Channels
98
Configuration Diagrams
100
NX5820 Channel Assignments and Configurations
100
Single Domain Typical Channel Configuration
101
Dual Domain Typical Channel Configuration
102
PCITHRU Feature Card
103
Dual Domain Typical PCITHRU Card Location in the Internal and External Channel Racks
103
PCITHRU Slot Versus PCI Bridge Jumper Positions
104
Configuring QIC Tape and CD-ROM
105
Information Contained in the NX Systems I/O Configuration Guide
105
Configuring the Servers
107
How this Section Is Organized
107
VX1305 Servers
108
VX1305 Basic Features
108
Basic Features, VX1305 Servers
109
Road Map for Ordering VX1305 Servers
110
Server Components
111
Basic Server Components
111
Add-On Processor Board
112
Add-On Processor Board, VX1305 Servers
112
Additional Memory Packages
113
Connection Packages and Optional PCI Thru Card
113
Optional User Access Components
114
Single-Server to Multi-Server Upgrades VX1305
114
VX1305-BSE/-BSU Basic Components
112
VX4000-CP3 Optional User Access Components, VX1305 Servers
114
Configuration Guidelines VX1305
115
Configuration Guidelines, VX1305 Servers
115
VX1505 Servers
116
VX1305 Server CS Bus Cable Connection
115
VX1505 Basic Features
116
Basic Features, VX1505 Servers
117
Server Components
118
VX1505-BSE Processor Requirements
118
Road Map for Ordering VX1505 Servers
119
Basic Server Components and Optional Redundant Power Supply
120
VX1505-BSE/-BSU Basic Components
120
Processors
121
Memory Packages
121
Memory Packages, VX1505 Servers
121
Connection Packages and Optional PCI Thru Card
122
Processors, VX1505 Servers
121
Connection Package Components, VX1505 Servers
122
Optional User Access Components
123
Single-Server to Multi-Server Upgrades VX1505
123
VX4000-CP3 Optional User Access Components, VX1505 Servers
123
Configuration Guidelines VX1505
124
Configuration Guidelines, VX1505 Servers
124
ES5085R Servers
125
VX1505 Server CS Bus Cable Connection
124
Basic Features
125
Basic Features, ES5085R Servers
126
Server Components
127
Road Map for Ordering ES5085R Servers
128
Processors
129
Memory Packages
129
Processors, ES5085R Servers
129
Connection Packages and Optional PCI
130
Optional User Access Components
131
Configuration Guidelines ES5085R
131
Servers
131
ES5085R Server CS Bus Cable Connection
131
VX4000-CP3 Optional User Access Components, ES5085R Servers
131
ES2024R Servers
132
Basic Features
132
Basic Features, ES2024R Servers
133
Server Components
134
Road Map for Ordering ES2024R Servers
135
Processors
136
Memory Packages
136
Processors, ES2024R Servers
136
Connection Packages and Optional PCI
137
Connection Package Components, ES2024R Servers
137
Optional User Access Components
138
Configuration Guidelines ES2024R
138
ES2024R Server CS Bus Cable Connection
138
VX4000-CP3 Optional User Access Components, ES2024R Servers
138
ES5044R Servers
139
Basic Features
139
Basic Features, ES5044R Servers
140
Server Components
141
Road Map for Ordering ES5044R Servers
142
Processors
143
Memory Packages
143
Processors, ES5044R Servers
143
Connection Packages and Optional PCI
144
Optional User Access Components
145
Configuration Guidelines ES5044R
145
ES5044R Server CS Bus Cable Connection
145
VX4000-CP3 Optional User Access Components, ES5044R Servers
145
Configuring the Private Maintenance Hub and Public Switching LAN
146
Configuring Single Domain Maintenance Hub and One Switching LAN
146
Configuring Single Domain Maintenance Hub and Two Switching Lans
148
Configuring Dual Domain Maintenance Hub and One Public Switching LAN
151
Configuring Dual Domain Maintenance Hub and Two Public Switching
153
Configuring Optional and Recommended UPS
156
Single Scp/Server to UPS Status Cable Connections (Site UPS Installed)
159
Dual Scp/Server to UPS Status Cable Connections (Site UPS Installed)
160
SCP to UPS Status Cable
161
Standalone (Prc1000I) UPS to SCP Cabling
161
Connecting Other Host Systems
163
Guidelines for Connecting Other Host Systems
163
Glossary
165
Configuring Dual Domain Maintenance Hub and Two Public Switching Lans
171
Connection Package Components, ES5044R Servers
172
Connection Package Components, ES5085R Servers
172
Connection Package Components, VX1305 Servers
172
Memory Card Slot Locations
172
Memory Packages, ES2024R Servers
172
Memory Packages, ES5044R Servers
172
Memory Packages, ES5085R Servers
172
Memory Packages, VX1305 Servers
172
Status Selection between Scp's and Servers
173
UPS Options
173
Advertisement
Advertisement
Related Products
Unisys NX5820 K
Unisys 5400B G1
Unisys Aquanta CP Series
Unisys CWP 50021
Unisys ES5000
Unisys Categories
Printer
Server
Scanner
Wireless Router
Card Reader
More Unisys Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL