Thermal Expansion; Strange Sounds; Operational Conditions; Smelly Water - Maytag HE21250PC User Manual

Series twelve pc intelligent electric water heater
Table of Contents

Advertisement

Troubleshooting
Start Up Conditions
THERMAL
EXPANSION
SmeUy water may be eliminated or reduced in some water heater
models by replacing the anode(s) with one of less active material,
Water supply systems may, because of such events as high line
and then chlorinating the water heater tank and all hot water
pressure, frequent cut-offs, the effects of water hammer
fines. Call Maytag Customer Service at 1-800-788-8899 for an
among others, have installed devices such as pressure reducing
authorized servicerfor further information concerning an Anode
valves, check valves, back flow preventers, etc._to control
Replacement Kit #66001068 and this Chlorination Treatment.
these types of problems. When these devices are not equipped
with an internal by-pass, and no other measures are taken, the
If the smelly water persists after the anode replacement and chlo-
devices cause the water system to be closed. As water is heat-
rinafion treatment, we can only suggest that continuous chlorina-
ed, it expands (thermal expansion) and dosed systems do not
tion and filtering conditioning equipment be considered to efimi-
allow for the expansion of heated water,
hate the water problem.
The water within the water heater tank expands as it is heated
Do not remove the anode leaving the tank unprotected. By
and increases the pressure of the water system. If the relieving
doing so, all warranty on the water heater tank is voided.
point of the water heater's temperature-pressure refiefvalve is
reached, the valve will relieve the excess pressure. The temper-
"AIR"
IN HOT WATER
FAUCETS
ature-pressure relief valve is not intended for the constant
relief of thermal expansion. This is an unacceptable condition
[
A
WARNING
and must be corrected.
/HYDROGEN GAS: Hydrogen gas can be produced in
|a hot water
system that has not been used for a
It is recommended that any devices installed which could create
|long
period of time (generally two weeks or more).
a closed system, have a by-pass and/or the system have an
/Hydrogen
gas is extremely
flammable
and explo-
expansion tank to relieve the pressure built by thermal expan-
_sive. To prevent the possibility of injury under these
sion in the water system.Expansiontanks are availablefor
conditions, we recommend the hot water faucet be
_opened for several
minutes
at the kitchen
sink
ordering through the Maytag Customer Service. Contact the
before any electrical appliances which are connect-
local water supplier and/or call Maytag Customer Service at
ed to the hot water
system are used (such as a dish-
1-800-788-8899
for an authorized servicer for assistance in
washer or washing machine). If hydrogen gas is pre-
sent, there will probably be an unusual sound simi-
controlling thesesituations,
lar to air escaping through
the pipe as the hot
water faucet is opened. There must be no smoking
STRANGE SOUNDS
or open flame near the faucet at the time it is open.
Possible noises due to expansion and contraction of some
RUMBLING
NOISE
metal parts during periods of heat-up and cool-down do not
represent harmful or dangerous conditions.
In some water areas, scale or mineral deposits will build up on
your heating elements. This buildup will cause a rumbling
noise. Follow "Element Cleaning/Replacement"
instructions
Operational Conditions
to clean and replace the elements.
SMELLY WATER
HIGH
TEMPERATURE
SHUT
OFF SYSTEM
In each glssslined water heater there is installed at least one anode
The water heater has a high limit shut offsystem with a reset
rod (see parts section) for corrosion protection of the tank,
button located above the upper element.
Certain water conditions will cause a reaction between this rod
and the water. The most common complaint associated with the
Follow the resetting instructions which refer to the high limit
anode rod is one of a "rotten egg smell". This odor is derived from
behind the access panel.
hy&ogen sulfide gas dissolved in the water. The smell is th_ result
of four factors which must all be present for the odor to develop:
a. a concentration of sulfate in the supply water.
b. tittle or no dissolved oxygen in the water.
c. a sulfate reducing bacteria within the water heater. (This
harmless bacteria is non-toxic to humans.)
d. an excess of active hydrogen in the tank. This is caused by
the corrosion protective action of the anode.