Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the
instructions provided with any tools listed here.
Flat-blade screwdriver
#2 Phillips screwdriver
Adjustable wrench that opens to 1"
(2.54 cm) or hex-head socket wrench
(for adjusting dryer feet)
Wire stripper (for U.S. only, direct wire
installations)
Parts supplied
Remove parts packages from dryer drum. Check that all parts are included.
Parts needed
Check local codes. Check existing electrical supply and venting. See "Electrical
Requirements" and "Venting Requirements" before purchasing parts.
Mobile home installations require metal exhaust system hardware available for purchase from
the dealer from whom you purchased your dryer. For further information, please refer to the
"Assistance or Service" section.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should
contain:
A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be
type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned ends.
A UL listed strain relief.
4

INSTALLATION INSTRUCTIONS

Tin snips (new vent installations)
Level
Vent clamps
Caulking gun and compound (for
installing new exhaust vent)
Tape measure
4 Leveling legs

Location Requirements

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. See "Venting Requirements."
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical outlet located within 2 ft
(61 cm) of either side of the dryer. See "Electrical Requirements."
A sturdy floor to support the total weight (dryer and load) of 200 lbs (90.7 kg). The
combined weight of a companion appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. (If slope is greater
than 1" [2.5 cm], install Extended Dryer Feet Kit, Part Number 279810.) Clothes may not
tumble properly and models with automatic sensor cycles may not operate correctly if
dryer is not level.
Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer
might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be exposed to water and/or
weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in
garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.

Hide quick links: