SiBE041134EB
4.5
Jumper Settings
Indoor Unit
Fan speed setting when
compressor stops for
thermostat OFF. (effective only
in cooling operation)
Power failure recovery function
For the location of the jumper, refer to page 12.
Outdoor Unit
Improvement
of defrost
performance
For the location of the jumper, refer to page
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
Trial Operation and Field Settings
Function
Function
RXS20/25K2V1B → J5
RXS20/25K3V1B → J5
RXS20/25L2V1B → J5
ARXS25L2V1B → J5
Jumper
When connected
(factory setting)
JB
Fan speed setting ;
Remote controller
setting
JC
Auto-restart
Jumper
Jumper: connected
(factory setting)
Standard control
.
14
When cut
The fan stops.
The unit does not resume
operation after recovering from a
power failure. Timer settings are
cleared.
Switch: OFF
Switch: ON
Jumper: cut
Reinforced control (Ex:
The frequency increases,
the duration time of
defrost lengthens.)
Field Settings
111