3.6-Inch Wall Mount Touchpanel
SCREEN SETTINGS
TIMEOUT SETTINGS

DIAGNOSTICS MENU

10 • 3.6-Inch Wall Mount Touchpanel: TPS-4L
Screen Settings
From the SETUP MENU, press the Screen Settings button to open the SCREEN
SETTINGS screen, shown at left.
Press the Brightness button to open the SCREEN SETTINGS – BRIGHTNESS
screen. Use the UP/DOWN buttons to set the display brightness (0 – 100%). The
area to the right of the buttons shows the relative brightness from 0% to 100%, both
as a numeric value and, for quick visual reference, as an analog bar.
Press the Key Backlight button to open the SCREEN SETTINGS – KEY
BACKLIGHT screen. Use the UP/DOWN buttons to set the key backlight brightness
(0 – 100%). The area to the right of the buttons shows the relative brightness from
0% to 100%, both as a numeric value and, for quick visual reference, as an analog
bar.
Press the LCD Bias button to open the SCREEN SETTINGS – LCD BIAS screen.
Use the UP/DOWN buttons to set the LCD bias (0 – 255). Use the graphic on the
right side of the screen to see the effects of the adjustment. The bias setting is best
when the lines are crisp and dark and the white area around them is bright.
Press Return to save the settings and return to the SETUP MENU.
Timeout Settings
From the SETUP MENU, press the Timeout button to open the SCREEN
SETTINGS – TIMEOUT screen. Use the UP/DOWN buttons to set the timeout
from 0 through 120 minutes, where 0 disables the timeout. Adjustment is in one-
minute increments from 1 to 10; in ten-minute increments from 20-120.
STANDBY timeout turns the display and backlight off when the touchpanel is
inactive for the specified time. When the touchpanel is reactivated, the last screen to
be displayed reappears. The specified time is displayed in minutes. The default
STANDBY timeout is 10 minutes.
Press Return to save the settings and return to the SETUP MENU.
Diagnostics Menu
The Diagnostics button from the MAIN MENU should only be used under
supervision from a Crestron customer service representative during telephone
support. Many options available from the DIAGNOSTICS MENU, shown to the left,