1. µcom/DSP Version display mode

1.1. Operation specifications

µcom/DSP version display mode:
When started up, the version information is displayed.
Starting up:
With the "DIMMER" and "STATUS" buttons pressed, press the "ON/OFF" button to turn the power on.
Now, press the "STATUS" button to the display the 2nd item information on the FL Display.
1.2. Display Order
Destination information → Main-µcom version information → Sub-µcom version information → DSP version information
→ APLD version information
1.3. Error display g
See the following table for each "Error information" display and its contents (status).
Display order is ①②③④ .
Condition
Sub-µcom
No response from Sub-µcom
NG
No response from DIR
DIR NG
When DSP boot, executing DSP reset makes no change to DSP FLAG0
DSP NG
port "H".
No change to DSP FLAG0 port "H" before issuing DSP command.
When DSP data read, executing WRITE="L" makes no change to ACK="H". "□DSP□□ERROR□03□ □"
When DSP data read, executing REQ="L" makes no change to ACK="L".
When DSP data write, executing WRITE="H" makes no change to ACK="H".
When DSP data write, executing REQ="L" makes no change to ACK="L".
When DSP special code boot, executing DSP reset makes no change to
DSP FLAG0 port "H".
No change to DSP FLAG0 port "H" before issuing DSP special read com-
mand.
No change to DSP FLAG0 port "H" before DSP version read.
Both SUB/DSP
OK
State
18
AVR-1910/1620/1610/790/590
Display
"□SUB□ □ERROR□01□□"
"□DIR□ □ERROR□01□□"
"□DSP□□ERROR□01□ □"
"□DSP□□ERROR□02□ □"
"□DSP□□ERROR□04□ □"
"□DSP□□ERROR□05□ □"
"□DSP□□ERROR□06□ □"
"□DSP□□ERROR□11□ □"
"□DSP□□ERROR□12□ □"
"□DSP□□ERROR□13□ □"
(No error display, version display
only)