Replacing A Hard Disk Module - Fujitsu PRIMERGY BX620 S4 Operating Manual

2-way server blade
Hide thumbs Also See for PRIMERGY BX620 S4:
Table of Contents

Advertisement

Hard Disk Drives
Figure 17: Inserting and engaging the hard disk module
– Swivel the locking lever toward the housing in the direction of the arrow and
press on it until it engages. Make sure you do not press on the ejection tab
with the punched-out triangle.
8.1.2

Replacing a Hard Disk Module

You can only replace a hard disk module during operation if the orange LED on
the hard disk module is glowing continuously, i.e. when an error has occurred.
V
ATTENTION!
Never remove a hard disk module during operation if you are not sure
that the hard disk module belongs to a disk array that operates at RAID
level 1, i.e. the disks are mirrored.
To replace a hard disk module during operation, proceed as follows:
Ê Press on the green ejection tab in the direction of the punched-out triangle
and pull the defective hard disk module out a few centimeters, holding it by
the opened lever.
Ê Wait at least 60 seconds so that the RAID controller can recognize that a
hard disk module has been removed and the hard disk can come to a stand-
still.
Ê With the locking lever open, pull out the hard disk module completely.