Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
P38DF Indoor
P Series
Residential
Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Immediately call your gas supplier from a neighbor's phone. Follow the gas
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Flammable materials
falling objects
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
C
®
US
150204.1

Advertisement

Table of Contents
loading

Summary of Contents for Montigo P38DFNI

  • Page 1 Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects ® XG0193 150204.1 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    P38DF* Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for future reference and maintenance. Table of Contents Instruction Manual Contents Operation Safety Alerts Maintenance Introduction General Section A: Before You Start...
  • Page 3: Safety Alerts

    Introduction Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Section A: Before You Start

    Should it be impossible to meet the venting requirements laid „ instructions and all applicable codes. out in Section 3: Venting, please contact a local Montigo dealer BEFORE YOU START: regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight „...
  • Page 5: Rating Plate Sample

    P38DF* Indoor Gas Fireplace Installation Rating Plate Sample Figure A: Rating Plate for P38DF-F IPI Electronic Ignition Page 5 XG0193 -150204.1...
  • Page 6: Section 1: Installation Overview And Product Dimensions

    P38DF* Indoor Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions selecting the fireplace location. Try to select a location that does not Please review the Installation Checklist on Page 4 for general information interfere with room traffic, has adequate ventilation and offers an on preparing for a successful installation of your fireplace.
  • Page 7: Section 2: Framing

    P38DF* Indoor Gas Fireplace Installation Section 2: Framing Frame in the enclosure for the unit with framing materials. The N.G. & L.P. framed opening for the assembled fireplace is 37 3/4" wide, x 41 1/4" Top Vent Ceiling high x 20 1/8" deep, see Figure 2 Alcove area over Fireplace,...
  • Page 8: Clearances

    P38DF* Indoor Gas Fireplace Installation Clearances Installing the Nailing Flange Extension When installing a shelf over the top of the fireplaces, the following guidelines must be adhered to: Before installing the supplied nailing flange extension, fold tabs at bottom For Rear Vent applications, the minimum clearance is 0" from the rear of nailing flange to a 90 degree angle.
  • Page 9: Section 3: Venting

    Should it be impossible to ensure that the termination is the highest point or to Flue Cover Plate meet the venting guidelines laid out below please contact your Montigo Flue Gasket dealer to discuss power venting options.
  • Page 10: Section 3-2: Installing A Roof Mounted Direct Vent Termination (Pvtk-1)

    P38DF* Indoor Gas Fireplace Installation Section 3-2: Installing a Roof Mounted Direct PVTK1 Vent Termination (PVTK-1) Termination This section applies to installations where the direct vent termi- 2’ min. nation will be roof mounted. Support ring Section 3-2-1: Venting Layout Support plate Selection of components and details of venting lay out should 32’...
  • Page 11 P38DF* Indoor Gas Fireplace Installation PVTK1 Termination PEXT Sections Support plate 32’ max Support ring 12” Max. Figure 9c. Rear vent, Roof mounted venting (1 = 90° bend). Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.
  • Page 12: Section 3-3: Installing A Wall Mounted Direct Vent Termination

    P38DF* Indoor Gas Fireplace Installation Section 3-3: Installing a Wall Mounted Direct 4). Installation of termination from inside structure A Termination with a MOSR Frame is installed from the inside of the Vent Termination structure. These are commonly used in high-rise construction. This section applies to installations where the direct vent termination will be wall mounted.
  • Page 13: Section 3-3-1: Venting Layout: Wall Mounted Termination

    If your installation does not fall from center of the vent pipe. within the venting parameters, 44 ” please contact a local Montigo Venting runs must fall within the limits set by the venting graph, „ dealer for Power Venting options.
  • Page 14 P38DF* Indoor Gas Fireplace Installation 45° Corner Installation. 45° or less Corner Installation. Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the PXT- Use a PTO-4 termination and an PFL-1 or PFL-2 (12" or 24" 20 to suit, and attach it to the PEL-45. Slide the fireplace into position compressed length) and a frame, if appropriate.
  • Page 15 If your installation does not fall or 15a with an 'X'. within the venting parameters, please contact a local Montigo If the 'X' falls on or above the top boundary of the shaded area, the dealer for Power Venting options.
  • Page 16: Section 3-3-2: Venting Components

    PEXT - 1 (12" f/m Section) possible hot spots. PEXT - 2 (24" f/m Section) Montigo recommends the use of a flex section for the final pipe PEXT - 3 (36" f/m Section) „ PEXT - 4 (48" f/m Section) connected directly to the fireplace offering greater flexibility of PEXT - 6 (72"...
  • Page 17: Section 3-3-3: Heat Shields

    P38DF* Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. The RHS101 Heat shield MUST be used where the RHS8 Termination (Figure 17 and 17a) CANNOT be used. Use the RHS101 where any Installing a Wall Mounted RHS8 Heat shield of the dimensions are within the parameters shown, figure 17a.
  • Page 18: Section 4: Wiring

    P38DF* Indoor Gas Fireplace Installation Section 4: Wiring Models P38DFNI P38DFLI BATTERY PACK 1.5V AA type 1.5V AA type SPARK GREEN 1.5V AA type MAIN WHITE Power 1.5V AA type BLACK BLACK 120VAC 60 Hz SENSOR 6 Amps MAIN ON/OFF...
  • Page 19: Section 5: Installing The Gas Line

    When pressure testing the fireplace, Gas line, and input system follow the appropriate in your model number local codes or your area. DO NOT connect the fireplace to pressures in excess of If gas type is not compatible, contact your local Montigo 1/2lb. This will damage the gas control valve. representative.
  • Page 20: Section 6: Finishing

    P38DF* Indoor Gas Fireplace Installation Section 6: Finishing Mantels & Surrounds Finishing Around the Fireplace NOTE: National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials. Non-combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project New technology, to meet consumer and government demands for the beyond shaded area shown in Figure 22.
  • Page 21: Section 7: Screen Installation And Removal

    P38DF* Indoor Gas Fireplace Installation Section 7: Screen Installation and Removal Left Side Detail Upper Screen Studs Upper Screen Removing / Attaching Screens: Stud Catch To Remove Screens: Grasp each top outer corner of the screen with your thumb and finger and pull towards yourself.
  • Page 22: Section 8: Installing & Removing The Door

    P38DF* Indoor Gas Fireplace Installation Section 8: Installing & Removing the Door Removing the door: The P38DF* doors are removed in a few simple steps. Follow these instructions below to remove the Horizontal access panel, unlatch the Step 4: door buckles and, remove the door. Replace in reverse order. Firmly grasp hand-hold end of Door buckle tool and place the machined...
  • Page 23 P38DF* Indoor Gas Fireplace Installation Step 8: Removing the Door: Grasp the Door on either side, usually midway and lift upward, lift the door carefully up and away from the front of the fireplace. See Figures 24g. Place the Door aside in a safe place while maintenance and / or cleaning is being performed.
  • Page 24: Section 9: Installing The Accessories

    P38DF* Indoor Gas Fireplace Installation Section 9: Installing the Accessories Installing the Firestones The P38DF* is supplied with firestones. Remove the Door as shown in the previous Instruction. Follow these instructions to ensure all parts are removed or replaced as required. Once the Trim and glass door is removed place the firestones randomly across the pan and the burners as described in Figure 25 to 25f.
  • Page 25: Installing Optional Speckled Stones

    P38DF* Indoor Gas Fireplace Installation Installing Optional Speckled Stones [RR250SS] Once the glass door has been removed as shown in the previous section, place the speckled stones evenly across the pan and burner. Ensure stones do not overlap too much as this will effect the flame pattern, see figure 25g.
  • Page 26 P38DF* Indoor Gas Fireplace Installation Installing Optional Speckled Stones The P38DF* has the option of installing a drift wood log set. Once the firestones or speckled stones have been installed the log set can be installed. Ensure logs are securely placed and will not tip or fall. Remove media where logs touch the burner tray to ensure a more secure position.
  • Page 27 P38DF* Indoor Gas Fireplace Installation Step 9. Place log 1 from LGS59 on top of log 4 from Step 7. Place log 5 from LGS59 in the back left corner LGS58. Place log 6 from LGS58 on top of log 4 from of the burner, behind the pilot.
  • Page 28: Sit Proflame 2 Electronic Ignition

    P38DF* Indoor Gas Fireplace Operation Operation For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. WARNING/ CAUTION: Hot while in operation.
  • Page 29: Maintenance

    P38DF* Indoor Gas Fireplace Maintenance Maintenance Lighting Instructions See page 27. General Pilot Burner Adjustment. Have the fireplace and installation inspected yearly. The inspection must 1. Locate Pilot Adjustment Screw. (See figure 26) include, but is not limited to, the following: 2.
  • Page 30: Troubleshooting

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 30...
  • Page 31: Replacement Parts

    P38DF* Indoor Gas Fireplace Appendix Replacement Parts: Replacement Parts List - SIT IPI Proflame 2 P38DF RGC3033 NG Gas Valve (with stepper motor) RGC3034 LP Gas Valve (with stepper motor) RPA035 NG Pilot Assembly RPA036 LP Pilot Assembly RGC3075 Ignitor Probe Assembly RGC3076 Flame sensor rod assembly RPTA03...
  • Page 32: Appendix A: Venting Terminations

    P38DF* Indoor Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 12 inches 12 inches 9 inches clearance to sides or bottom of door or operable windows...
  • Page 33: Appendix B: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 34: Appendix C: State Of Massachusetts

    P38DF* Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 35 P38DF* Indoor Gas Fireplace Notes Notes Page 35 XG0193 -150204.1...
  • Page 36 P38DF Single Sided Gas Fireplace XG0193 - 150204.1...

This manual is also suitable for:

P38dfliP38dfl