Fabric zoning and LUN security for multiple operating systems

You can connect multiple clusters with multiple operating systems to the same switch and fabric
using appropriate zoning and LUN security as follows:
Storage port zones can overlap if more than one operating system needs to share an array
port.
Heterogeneous operating systems can share an array port if you set the appropriate host
group and mode. All others must connect to a dedicated array port.
Use LUN Manager for LUN isolation when multiple hosts connect through a shared array port.
LUN Manager provides LUN security by allowing you to restrict which LUNs each host can
access.
Table 24 Fabric zoning and LUN security settings (Linux)
Environment
Standalone SAN
(non-clustered)
Clustered SAN
Multi-Cluster SAN

Connecting the disk array

The HP service representative performs the following steps to connect the disk array to the host:
1.
Verifying operational status of the disk array channel adapters, LDEVs, and paths.
2.
Connecting the Fibre Channel cables between the disk array and the fabric switch or host.
3.
Verifying the ready status of the disk array and peripherals.

Restarting the Linux server

To recognize the new device(s), restart the Linux server as follows:
1.
Power on the display of the Linux server.
2.
Power on all devices other than the Linux server.
3.
Confirm ready status of all devices.
4.
Power on the Linux server.

Verifying new device recognition

Verify that the FCA driver is installed using the sr-probe command.
# xe sr-probe type=lvmohba
Error code: SR_BACKEND_FAILURE_107
Error parameters: , The SCSIid parameter is missing or incorrect, <?xml version="1.0" ?>
<Devlist>
<BlockDevice>
<path>
/dev/sdw [sde] [sda]
</path>
<numpaths>
4
</numpaths>
<SCSlid>
3600508b40008122b0000600000430000 <--- XP Device SCSI device
</SCSlid>
<vendor>
HP
</vendor>
<serial>
P5512G19SVC01E
</serial>
<size>
48318382080
</size>
98
Citrix XenServer Enterprise
OS Mix
homogeneous (a single OS type present
in the SAN)
heterogeneous (more than one OS type
present in the SAN)
Fabric Zoning
Not required
Must be used when multiple
hosts or cluster nodes connect
through a shared port
Required
LUN Security

Advertisement

Table of Contents
loading

Table of Contents