Storage - Echo PB-2155 Operator's Manual

Hide thumbs Also See for PB-2155:
Table of Contents

Advertisement

24
S
TORAGE
Long Term Storage (Over 30 Days)
Do not store your unit for a prolonged period of time (30 days or longer)
without performing protective storage maintenance which includes the
following:
1. Store unit in a dry, dust free place, out of the reach of children.
WARNING
Do not store in enclosure where fuel fumes may accumulate or
reach an open flame or spark or serious personal injury may
result.
2. Place the ignition switch in the "STOP" position.
3. Remove accumulation of grease, oil, dirt and debris from exterior of
unit.
4. Perform all periodic lubrication and services that are required.
5. Tighten all screws and nuts.
6. Drain the fuel tank completely and pull the recoil starter handle
several times to remove fuel from the carburettor.
7. Remove the spark plug and pour 1/4 oz. (1/2 tablespoon) of fresh,
clean ECHO 2-stroke engine oil into the cylinder through the spark
plug hole.
A. Place a clean cloth over the spark plug hole.
B. Pull the recoil starter handle 2-3 times to distribute the oil
inside the engine.
C. Observe the piston location through the spark plug hole.
Pull the recoil starter handle slowly until the piston reaches the
top of its travel and leave it there.
8. Install the spark plug (do not connect ignition cable).
9. Remove blower pipe assembly from unit.