Storage; Long Term Storage (Over 30 Days) - Echo PB-265LN Operator's Manual

Hide thumbs Also See for PB-265LN:
Table of Contents

Advertisement

STORAGE

STORAGE
During operation the muffler or catalytic muffler and
surrounding cover become hot. Always keep exhaust area clear
of flammable debris during transportation or when storing,
otherwise serious property damage or personal injury may
result.

Long Term Storage (Over 30 Days)

Do not store your unit for a prolonged period of time (30 days or longer)
without performing protective storage maintenance which includes the
following:
1.
Store unit in a dry, dust free place, out of the reach of children.
Do not store in enclosure where fuel fumes may accumulate or
reach an open flame or spark.
2.
Place the stop switch in the "OFF" position.
3.
Remove accumulation of grease, oil, dirt and debris from exterior of
unit.
4.
Perform all periodic lubrication and services that are required.
5.
Tighten all the screws and nuts.
6.
Drain fuel tank completely. Press purge bulb 6 -7 times to remove
remaining fuel from carburetor then drain the tank again. Close choke,
start and run the engine until it stops due to lack of fuel.
7.
Allow engine to cool then remove the spark plug and pour 7 cc (1/4 oz.)
of fresh, clean, two-stroke engine oil into the cylinder through the spark
plug hole.
8.
Pull the recoil starter handle 2-3 times to distribute the oil inside the
engine.
9.
Observe the piston location through the spark plug hole. Pull the recoil
handle slowly until the piston reaches the top of its travel and leave it
there.
10. Install the spark plug (do not connect ignition cable).
11. Remove blower pipe assembly from unit.
38
PB-265LN
X7501184901
© 03/2019 ECHO Inc.