Make Electrical Connection - Jenn-Air LI3UNC/W10274316C Installation Instructions And Use & Care Manual

30", 36", and 48" (76.2 cm, 91.4 cm, and 121.9 cm) commercial style wallmount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

4. Align mounting holes and install 5 - 6 x 16 mm screws.
A
B
A. Screw
B. Mounting hole
5. Attach power cord connector to connector on wire box on
blower motor mounting plate.
B
C
A. Blower motor mounting plate
B. Wire box connector
C. Power cord
10
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Locate junction box inside of the range hood.
A

Make Electrical Connection

WARNING
Electrical Shock Hazard
A. Terminal box cover
B. Knockout in canopy back into terminal box
A
B
C
D
A. White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/green wires
E. Home power supply
F. UL listed or CSA approved
B
A
E
F
¹⁄₂
" strain relief