Reinstall Motor; Make Electrical Connection - Jenn-Air 36" Installation Instructions And User Manual

(91,4 cm) wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

1. Place the motor into the module housing positioning
it with
the large keyholes in motor mounting plate towards the back
of the canopy.
2. Grasping the motor plate, push the motor up into the module
housing. Locate the large keyholes over the motor mounting
nuts, push up against the module top cover and pull the
motor forward to lock into the small keyholes slots.
3. Use the special 1/2"(13 mm) tool and tighten the (4) nuts to
secure the motor.
For 3 Prong Grounded
Power
Cord:
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
1. Plug 3 prong power cord into a grounded 3 prong outlet
located above the range hood.
For Hard Wire from Home Power Supply:
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect
power.
2. Remove the terminal box cover.
A
A. Screws
B. Terminal box cover
3. Disconnect
grounded power cord wires from terminal block.
Loosen the screws labeled "L," "N," and "Ground Symbol."
4. Remove power cord strain relief from terminal box and
remove power cord.
A
®
B
A. Power cord
B. Power cord strain relief
C. Location
"L" (black wire)
D. Location
"N" (white wire)
E. Location ground symbol (green or bare ground wire)
5. Install a UL listed or CSA approved V2" strain relief.
12