Mantel Requirements; Combustible Mantels; Examples; Non-Combustible Mantels - Travis Industries 864 TRV Deluxe Installation Manual

(with screen)
Hide thumbs Also See for 864 TRV Deluxe:
Table of Contents

Advertisement

Mantel Requirements

Combustible Mantels

Use the table below to determine the maximum mantel depth allowed. The mantel depth (measured
from the face of the fireplace) must fall in the shaded portion of the table.
Any material that protrudes more than 3/4" (19mm) from the non-combustible facing is considered a
mantel and must meet the mantel requirements.
Maximum Mantel Depth (b)
356mm (14+")
330mm (13")
305mm (12")
279mm (11")
254mm (10")
229mm (9")
Mantel
203mm (8")
Height
178mm (7")
Above
152mm (6")
Face (a)
127mm (5")
102mm (4")
76mm (3")
51mm (2")
25mm (1")
0mm (0")

Examples:

- If you wish to have an 8" (203mm) deep mantel, it must be at least 8" (203mm) above the fireplace face (44-3/4", 1137mm above the base).
- If you wish to have a mantel 6" (152mm) above the fireplace face, it must be no deeper than 6" (152mm).

Non-Combustible Mantels

Non-combustible mantels must meet the clearances listed for combustible mantels. However, if you do
wish to reduce the clearances by using a non-combustible mantel, the following requirements must be met:
Non-combustible
mantel and facing
must extend from the
top of the appliance to
the top surface of the
mantel.
A non-combustible
header must be used
(metal stud).
Travis Industries
Installation
(for qualified installers only)
Combustible Mantel
Non-Combustible Framing (metal studs)
must be used for the header.
b
a
36-3/4"
933mm
Base of the Fireplace
SIDE OF FIREPLACE
4140611
Combustible mantel columns (legs) that protrude
more than 3/4" (.75mm) from the glass frame must
meet the sidewall clearance. If they protrude 3/4"
(.75mm) or less, they must meet the facing
clearance, 2-1/4" (57mm) from the glass frame - to
the side of the fireplace, not in front of it.
Non-combustible mantel columns do not have a
minimum clearance.
Drywall
Non-Combustible Mantel
Non-Combustible Facing
100-01387