Rear Vent Configuration With Vertical Termination - Travis Industries 864 TRV Deluxe Installation Manual

(with screen)
Hide thumbs Also See for 864 TRV Deluxe:
Table of Contents

Advertisement

Rear Vent Configuration with Vertical Termination

The termination must fall
within the shaded area shown
in the chart. Use the
indicated restrictor and
diffuser positions.
Up to four elbows (45° or 90°)
may be used.
Only one horizontal elbow
may be used.
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
Travis Industries
Installation
(for qualified installers only)
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
H2
H1
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbow
4140611
31
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
100-01387