roubleshooting
Low Suction
Possible causes
1.
Disposable dust bag is full
2.
Wand is not properly installed
Poor Pick Up
Possible causes
1.
Tool not working properly
2.
Brush is worn out
Vacuum motor is not working
Possible causes
1.
Vacuum is not plugged in
2.
Electrical Outlet is not working
3.
Air path obstructed
4.
Vacuum is turned OFF
Other maintenance or service not included in the manual should be
performed by an authorized service representative.
SERVICE OR PARTS 1-877-977-3339
8
WARNING:
To reduce the risk of fire, electric
shock, or injury,turn power
OFF and disconnect plug from
electrical outlet before performing
maintenance or troubleshooting.
Remedies
1. Dispose current disposable bag and replace with new
2. Secure wand properly to ensure no air leaks
Remedies
1. Make sure tool is on the wand properly and tightly
2. Brush might need to be replaced
Remedies
1. Check to make sure vacuum is plugged in properly
2. Check electrical source
3. Check for any air flow obstructions
4. Check to make sure the vacuum button is ON