2.6

Toner Low Detection

Device
The Toner Low Detection device consists of a stirring gear which rotates at a constant rate,
a stirring bar and a magnet on the stirring bar. The stirring bar rotation is driven by the link to
the gouged portion in the stirring gear.
Magnet
Operation
Toner Low is detected by monitoring the time interval of the encounter of the magnet set on
the sensor plate and the magnet on the stirring bar.
Operation during Toner Full state
The stirring bar rotates due to the mechanical
transmission of energy originating from the
interlocking with the stirring gear.
Even when the magnet on the stirring bar
reaches the maximum height, the stirring bar
is pushed by the stirring gear, since the other
side is being dipped in the toner.
Operation during Toner Low state
When the stirring bar reaches the maximum
height, it falls to the minimum height due to its
own weight, since there is no resistance pro-
vided by the toner on the other side. Because
of this, the time interval during which it is in
encounter with the magnet of the sensor plate
becomes longer. By monitoring this time inter-
val, Toner Low state can be detected.
41154001TH Rev.2
Stirring Bar
Stirring Gear
Stirring Gear Section
Stirring Bar
Sensor Plate
Toner Sensor
Stirring Bar
Sensor Plate
Gouged
portion