Inspection And Adjustment Of Ae Ccd Alignment - Nikon D70 VBA10401 Repair Manual

Table of Contents

Advertisement

Inspection and adjustment of AE CCD Alignment

・ Procedure
① To prevent short circuit, attach the grip (#B26) with the
screw (#631).
② Connect 2 parts of the main SW FPC unit (#B1011) with
jumpers. * 2 parts = Red line as shown right
i.e. at lower left of the release SW and the 3rd soldering
bridge counting from the bayonet side.
③ Connect the camera and PC with the communication tool
(J61205) and MC-31 (J19109).
(ref. Page A35-A36 )
④ Provide power to camera via AC adapter EH-5.
* Note: Be careful of short circuit where there is no cover.
⑤ Start up the inspection and adjustment software for
D70 (J18361), and select "INSPECTION AND
ADJUSTMENT FOR AECCD POSITION" then "CCD
ALIGNMENT INSPECTION AND ADJUSTMENT".
⑥ By following instructions on PC, make the position ad-
justment of AECCD by 3 screws.
⑦ Select "CCD SLANT INSPECTION" of the adjustment
software and make an inspection.
⑧ After the adjustment, fix the AECCD by applying Aron
alpha (super glue) slightly.
⑨ Remove the communication tool (J61205).
⑩ Remove the jumper wire of ② .
⑪ Take out the screw (#631) and grip (#B26).
Outer LCD
・ Attach the outer LCD (#B2006) with 2
screws (#613).
・ Assemble the illumination SW unit by
aligning 2 bosses.
・ Make soldering bridges.
Lower left of
release SW
Y-direction
Adjustable
screw
#613×2
Soldering bridges
- A26 ・
-
VBA10401-R.3623.A
3rd soldering bridge count-
ing from bayonet side
#B1011
#631
#B26
Adhesive: Aron alpha
Illumination SW unit
#B2006
X-direction
Adjustable
screw
Boss×2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D70

Table of Contents