FUNAI D8B-M1000ZB Service Manual page 47

Dvd player & video cassette recorder
Table of Contents

Advertisement

Power Supply CBA Top View
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
Junction CBA
Junction CBA
Top View
Bottom View
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
BE8G00F01021B
Power Supply CBA Bottom View
Because a hot chassis ground is present in the power
supply circut, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly, when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
1-12-19
BE8G00F01021A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D8c-m1000db

Table of Contents