5. Use 3/8"nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10-32 hex nuts.
F
D
A. 10-32 hex nut
B. Ground-link
screw
C. Line 2 (red)
D. Green ground wire
E. Neutral (center) wire
F. Line 1 (black)
6. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
7. Firmly tighten hex nuts.
NOTE: For power supply cord replacement, use only a power
cord rated at 250 volts minimum, 40- or 50-amps that is
marked for use with nominal 13/8"(3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
8. Tighten strain relief screws.
IMPORTANT: Verify the tightness of the hex nuts.
9. Replace lower access cover.
Install Using Direct Wire
Electrical
Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper
or 6 gauge aluminum
wire.
Electrically ground
range.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
Direct wire strain relief
1. Disconnect
power.
2=
Remove the lower access cover screws located on the back
of the range. Pull the bottom of the cover toward you and out
to remove cover from range.
A
B
3=
A. Three mounting tabs
g. Lower access cover
C. Screws (2)
Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4. Assemble a UL listed conduit connector in the opening.
5=
jjj_
S
A. Removable retaining nut
B. Conduit
Tighten strain relief screw against the flexible conduit.