TROUBLESHOOTING
Problem
No AC output
is available,
but
generator
is running.
Generator
runs good at no=load
but "bogs"
down"
when
loads are
connected.
Generator
will not star_; or starts
and runs rough.
Generator
shuts down
during
operation.
Generator
lacks power.
Cause
I.
One of the circuit breakers is
open.
2.
Fault in generator.
3.
Poor connection
or defective
cord
set.
4.
Connected
device is bad.
I.
Short
circuit in a connected
load.
2.
Generator
is overloaded.
3.
Shorted
generator
circuit.
I.
Failed battery.
2.
Low oil level.
I.
Out of gasoline.
2.
Low oil level.
Correction
I.
Reset circuit breaker.
2.
Contact
Authorized
service
facility.
3.
Check and repair.
Load is too high.
4.
Connect
another
device that is in
good condition.
I.
Disconnect
shorted
electrical
load.
2.
See "Don't Overload
Generator".
3.
Contact
Authorized
service
facility.
I.
Replace battery.
2.
Fill crankcase
to proper
level or
place generator
on level surface.
I.
Fill fuel tank.
2.
Fill crankcase
to proper
[eve[ or
place generator
on level surface.
See "Don't
Overload
Generator".