Infinity high capacity continuous flow gas hot water system
Hide thumbs Also See for INFINITY 26i:
Table of Contents

Advertisement

2. Specifications

Model No.
Type of Appliance
Operation
Flue System
Installation
Available Default Temperatures (Note 1):
(without Remote Controllers)
Temperature Range (with Remote Controllers)
Dimensions (mm)
Weight (Kg)
Connections
Ignition System
Max. / Min. Gas
Consumption
Hot Water Delivery Capacity Max.
Noise level
Thermal Efficiency
NOXaf
Minimum Operating Water Flow:
Minimum Operating Pressure (Note 2):
Maximum Operating Water flow
Nominal Operat-
Less than 60°C
ing Pressure
Greater than or equal to 60°C
Power Supply
Remote Control (optional)
Water temperature control
Water flow
control
Safety Device
Combustion fan rpm check
Remote
Controllers
(optional)
Remote Controller Cable (Optional)
Electrical
Consumption
Manifold Electronic Control System (Optional)
Note 1: The default factory setting is 55ºC for the Infinity26i, and 65°C for HD50i. The unit can be ordered
from Rinnai to be pre-set to any of the other temperatures listed. The unit can be pre-set to any of the
temperatures listed by a suitably qualified person.
Controllers are available with default temperatures up to 75º C. When fitted with controllers, only
temperatures not exceeding the default temperatures can be selected. When fitted without controllers, the
unit will deliver water at the default temperature. Controllers are not available with 85° C settings.
Note 2: Unit will operate at lower pressures but the maximum rated flow of 32L/min. will not be achieved.
Infinity REU-V2632FFU / HD200I REU-V2632FFUC
Infinity 26i and HD50i
Width
Height
Depth
Gas
Cold Water Supply
Hot Water Supply
Natural Gas
Propane Gas
Infinity Unit
Flame Failure
Boil dry
Remaining Flame (OHS)
Over temperature
Fusible link
Pressure relief valve
Over current
Kitchen
Bathroom
Second Bathroom
Third Bathroom
Normal
Standby
Infinity 26i and HD50i
Temp.controlled continuous Flow Gas Hot Water Unit
With/without remote controls, mounted in Kitchen, bathroom
Room Sealed - Forced Draught Flue
Internally mounted (Indoor Only)
40º C, 43º C, 50º C, 55º C, 60º C, 65º C, 75º C, 85º C
(set by combination of Dip switches on PCB)
Kitchen controller
Bathroom controller
350
600
224
22
3/4 in. BSP
3/4 in. BSP
3/4 in. BSP
Direct Electronic Ignition
54 -- 4.4 kW
54 -- 4.4 kW
26 to 32 L/min.
49 dB(A)
87%
55 ppm Max.
2.4 L/min.
1.8 bar
32 L/min.
1.4 bar
2.0 ~ 10.0 bar
AC 230 Volts (50 Hz)
DC 12 Volts (Digital)
Simulation feedforward and feedback
Electronic Water flow sensor, flow control & heat exchanger
by-pass flow control.
Flame rod
Water flow sensor
97º C bi-metal switch
95º C lockout thermistor
129º C Thermal Fuse
Opens 20.6 bar, closes 14.7 bar
Integrated circuit system
Glass fuse (3 Amp).
MC91-1A or MC-70-2A
MC91-1A or BC-70-2A
MC91-1A or BC-70-2A
MC91-1A
Two core sheathed (double insulated) flex with min.cross-sectional area of 0.5 mm²
80W
7.5 W (with 1 Remote Control)
MSA-2M, MSA-2S
- 2 -
,
etc.
: 37 ~ 55º C
: 37 ~ 50º C
Issue 1 - 8/09/03 ©Rinnai